Back to search

Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients

Data up to Jan 2025

Published2005
Citations172
References40

Total Citations Per Year

Abstract

References (40)

Practical cone-beam algorithm

1984 • 5,913 citations

The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy

2000 • 1,403 citations

Flat-panel cone-beam computed tomography for image-guided radiation therapy

2002 • 1,288 citations

Physical aspects of a real-time tumor-tracking system for gated radiotherapy

2000 • 642 citations

Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter

2001 • 580 citations

Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration

1995 • 524 citations

Cone‐beam computed tomography with a flat‐panel imager: Initial performance characterization

2000 • 515 citations

Measurement of prostate movement over the course of routine radiotherapy using implanted markers

1995 • 356 citations

Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy

2003 • 348 citations

Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)

2005 • 343 citations

An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer

2000 • 315 citations

A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets

1999 • 311 citations

Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients

1998 • 306 citations

Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI

1999 • 277 citations

A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer

1999 • 259 citations

Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: A clinical study

1997 • 250 citations

Cone-beam-CT guided radiation therapy: technical implementation

2005 • 241 citations

Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

2002 • 220 citations

Optimization of x‐ray imaging geometry (with specific application to flat‐panel cone‐beam computed tomography)

2000 • 208 citations

Intrafraction prostate motion during IMRT for prostate cancer

2002 • 206 citations

Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers

2000 • 202 citations

Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer

2001 • 200 citations

Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility

1995 • 184 citations

Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)

2002 • 182 citations

Measurements and clinical consequences of prostate motion during a radiotherapy fraction

2002 • 163 citations

Helical Tomotherapy: An Innovative Technology and Approach to Radiation Therapy

2002 • 162 citations

Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy

2002 • 160 citations

Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers

2004 • 158 citations

Measurement of intrafractional prostate motion using magnetic resonance imaging

2002 • 154 citations

Target position variability throughout prostate radiotherapy

1998 • 136 citations

Short-course intensity-modulated radiotherapy for localized prostate cancer with daily transabdominal ultrasound localization of the prostate gland

2000 • 130 citations

Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials

2003 • 125 citations

Matched-Pair Analysis of Conformal High–Dose-Rate Brachytherapy Boost Versus External-Beam Radiation Therapy Alone for Locally Advanced Prostate Cancer

2000 • 123 citations

Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: implications for treatment margins

2003 • 115 citations

Three‐dimensional computed tomographic reconstruction using a C‐arm mounted XRII: Image‐based correction of gantry motion nonidealities

2000 • 110 citations

A comparison of ventilatory prostate movement in four treatment positions

2000 • 107 citations

Intrafractional stability of the prostate using a stereotactic radiotherapy technique

2003 • 67 citations

Design of adaptive treatment margins for non-negligible measurement uncertainty: application to ultrasound-guided prostate radiation therapy

2003 • 25 citations

First clinical experience with cone-beam CT guided radiation therapy; evaluation of dose and geometric accuracy

2004 • 15 citations

Treatment planning aids in prostate cancer: friend or foe?

2001 • 6 citations

Cited By (0)

No citing papers found in database

Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer… (2005) – International Journal of Radiation Oncology*Biology*Physics | Metascience Observatory Explorer