Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients
Data up to Jan 2025
Total Citations Per Year
Abstract
References (40)
Practical cone-beam algorithm
1984 • 5,913 citations
The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy
2000 • 1,403 citations
Flat-panel cone-beam computed tomography for image-guided radiation therapy
2002 • 1,288 citations
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
2000 • 642 citations
Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
2001 • 580 citations
Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
1995 • 524 citations
Cone‐beam computed tomography with a flat‐panel imager: Initial performance characterization
2000 • 515 citations
Measurement of prostate movement over the course of routine radiotherapy using implanted markers
1995 • 356 citations
Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy
2003 • 348 citations
Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)
2005 • 343 citations
An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer
2000 • 315 citations
A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets
1999 • 311 citations
Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients
1998 • 306 citations
Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI
1999 • 277 citations
A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer
1999 • 259 citations
Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: A clinical study
1997 • 250 citations
Cone-beam-CT guided radiation therapy: technical implementation
2005 • 241 citations
Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer
2002 • 220 citations
Optimization of x‐ray imaging geometry (with specific application to flat‐panel cone‐beam computed tomography)
2000 • 208 citations
Intrafraction prostate motion during IMRT for prostate cancer
2002 • 206 citations
Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers
2000 • 202 citations
Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer
2001 • 200 citations
Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility
1995 • 184 citations
Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
2002 • 182 citations
Measurements and clinical consequences of prostate motion during a radiotherapy fraction
2002 • 163 citations
Helical Tomotherapy: An Innovative Technology and Approach to Radiation Therapy
2002 • 162 citations
Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy
2002 • 160 citations
Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers
2004 • 158 citations
Measurement of intrafractional prostate motion using magnetic resonance imaging
2002 • 154 citations
Target position variability throughout prostate radiotherapy
1998 • 136 citations
Short-course intensity-modulated radiotherapy for localized prostate cancer with daily transabdominal ultrasound localization of the prostate gland
2000 • 130 citations
Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials
2003 • 125 citations
Matched-Pair Analysis of Conformal High–Dose-Rate Brachytherapy Boost Versus External-Beam Radiation Therapy Alone for Locally Advanced Prostate Cancer
2000 • 123 citations
Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: implications for treatment margins
2003 • 115 citations
Three‐dimensional computed tomographic reconstruction using a C‐arm mounted XRII: Image‐based correction of gantry motion nonidealities
2000 • 110 citations
A comparison of ventilatory prostate movement in four treatment positions
2000 • 107 citations
Intrafractional stability of the prostate using a stereotactic radiotherapy technique
2003 • 67 citations
Design of adaptive treatment margins for non-negligible measurement uncertainty: application to ultrasound-guided prostate radiation therapy
2003 • 25 citations
First clinical experience with cone-beam CT guided radiation therapy; evaluation of dose and geometric accuracy
2004 • 15 citations
Treatment planning aids in prostate cancer: friend or foe?
2001 • 6 citations
Cited By (0)
No citing papers found in database