Back to search

Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials

Data up to Jan 2025

Published2003
Citations125
References22

Total Citations Per Year

Abstract

References (22)

The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy

2000 • 1,403 citations

Organ motion and its management

2001 • 932 citations

Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability

1999 • 534 citations

Set-up verification using portal imaging; review of current clinical practice

2001 • 368 citations

Measurement of prostate movement over the course of routine radiotherapy using implanted markers

1995 • 356 citations

An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer

2000 • 315 citations

A verification procedure to improve patient set-up accuracy using portal images

1993 • 261 citations

Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: A clinical study

1997 • 250 citations

High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging

1996 • 215 citations

Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers

2001 • 206 citations

Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers

2000 • 202 citations

Daily prostate targeting using implanted radiopaque markers

2002 • 193 citations

Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation

2003 • 177 citations

Measurements and clinical consequences of prostate motion during a radiotherapy fraction

2002 • 163 citations

Internal organ motion in prostate cancer patients treated in prone and supine treatment position

1999 • 158 citations

Automatic three‐dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data

1996 • 146 citations

Routine clinical on-line portal imaging followed by immediate field adjustment using a tele-controlled patient couch

1992 • 119 citations

3-D portal image analysis in clinical practice: an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients

2000 • 116 citations

Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK)

2000 • 91 citations

Feasibility of automatic marker detection with an a-Si flat-panel imager

2001 • 55 citations

Modeling the effects of inhomogeneous dose distributions in normal tissues

2001 • 51 citations

Partial boosting of prostate tumours

2001 • 30 citations

Cited By (0)

No citing papers found in database

Comparison of megavoltage position verification for prostate irradiation based on bony… (2003) – Radiotherapy and Oncology | Metascience Observatory Explorer