Electrodeposited polytyramine as an immobilisation matrix for enzyme biosensors
Data up to Jan 2025
Total Citations Per Year
Abstract
References (50)
Enhancement by N-hydroxysulfosuccinimide of water-soluble carbodiimide-mediated coupling reactions
1986 • 865 citations
Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film
1990 • 561 citations
Enzyme entrapment in electrically conducting polymers. Immobilisation of glucose oxidase in polypyrrole and its application in amperometric glucose sensors
1986 • 526 citations
A review of the immobilization of enzymes in electropolymerized films
1993 • 471 citations
Electrochemical immobilisation of enzymes
1987 • 327 citations
Improving enzyme–electrode contacts by redox modification of cofactors
1995 • 235 citations
Enzyme microsensor for glucose with an electrochemically synthesized enzyme-polyaniline film
1988 • 228 citations
Membrane-covered, rotated disk electrode
1979 • 227 citations
A Biosensor Array Based on Polyaniline
1996 • 224 citations
The application of conducting polymers in biosensors
1993 • 216 citations
Use of polymer films in amperometric biosensors
1995 • 200 citations
A Glucose Biosensor Based on Immobilization of Glucose Oxidase in Electropolymerized o-Aminophenol Film on Platinized Glassy Carbon Electrode
1996 • 161 citations
Electrochemical immobilization of enzymes. 3. Immobilization of glucose oxidase in thin films of electrochemically polymerized phenols
1992 • 161 citations
The 3D structure of glucose oxidase from Aspergillus niger. Implications for the use of GOD as a biosensor enzyme
1993 • 160 citations
Research in Chemical Kinetics
1995 • 150 citations
Miniaturized Biosensors Employing Electropolymerized Permselective Films and Their Use for Creatinine Assays in Human Serum
1996 • 127 citations
Model of a two-substrate enzyme electrode for glucose
1984 • 125 citations
Electrochemical oxidation of H2O2 on Pt and Pt + Ir electrodes in physiological buffer and its applicability to H2O2-based biosensors
1993 • 124 citations
Covalent electropolymerization of glucose oxidase in polypyrrole
1992 • 109 citations
Reactions of Carbodiimides. I. The Mechanisms of the Reactions of Acetic Acid with Dicyclohexylcarbodiimide1,2
1966 • 108 citations
Über den einfluss inaktiver oberflächenbereiche auf den diffusionsgrenzstrom an rotierenden scheibenelektroden und die transitionszeit bei galvanostatischen messungen
1966 • 96 citations
Gesetzmässigkeit für den Diffusionsgrenzstrom an teilweise blockierten Modellelektroden
1968 • 93 citations
Obtaining thin films of “reactive polymers” on metal surfaces by electrochemical polymerization
1981 • 89 citations
Reactions of Carbodiimides. II. The Reactions of Dicyclohexylcarbodiimide with Carboxylic Acids in the Presence of Amines and Phenols1,2
1966 • 70 citations
Partial characterization in vitro of glucose oxidase‐modified poly(phenylenediamine)‐coated electrodes for neurochemical analysis in vivo
1994 • 70 citations
Lactate Amperometric Biosensor Based on an Electrosynthesized Bilayer Film with Covalently Immobilized Enzyme
1997 • 68 citations
Model for an Immobilized Oxidase Enzyme Electrode in the Presence of Two Oxidants
1994 • 58 citations
Zur Rührabhängigkeit des Grenzstromes an teilweise bedeckten rotierenden Scheibenelektroden bei relativ grossen Umdrehungszahlen
1969 • 56 citations
Redox enzyme linked electrochemical sensors: Theory meets practice
1995 • 55 citations
Immobilization of glucose oxidase in thin polypyrrole films: Influence of polymerization conditions and film thickness on the activity and stability of the immobilized enzyme
1993 • 54 citations
Modeling the kinetics of immobilized glucose oxidase
1987 • 53 citations
Rotated, membrane-covered oxygen electrode
1980 • 53 citations
An investigation of 3-functionalized pyrrole-modified glucose oxidase for the covalent electropolymerization of enzyme films
1994 • 39 citations
Behavior of glucose oxidase immobilized in various electropolymerized thin films
2000 • 37 citations
Enzyme immunosensors based on electropolymerized polytyramine modified electrodes
1990 • 36 citations
Membrane properties of acrylate bulk polymers for biosensor applications
1996 • 34 citations
A novel rotated disc electrode and time lag method for characterizing mass transport in liquid‐membrane systems
1980 • 32 citations
Electrochemical synthesis and sensor application of poly (1,4-diaminobenzene)
1996 • 32 citations
Covalent immobilisation of glucose oxidase on methacrylate copolymers for use in an amperometric glucose sensor
1993 • 32 citations
Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized in poly(mercapto-p-benzoquinone) film
1996 • 30 citations
Voltammetric and XPS Analysis of Metal‐Complexed Polytyramine Films : Geometry‐Dependent Electron Transfer Therein
1984 • 27 citations
Immobilisation of photosynthetic cells based on film-forming emulsion polymers
1994 • 26 citations
Glucose Sensitivity of Thiol-modified Gold Electrodes Having Immobilized Glucose Oxidase and 2-Aminoethylferrocene
1993 • 26 citations
Advanced immobilization and protein techniques on thin film biosensors
1992 • 25 citations
A biosensor for L‐amino acids using polytyramine for enzyme immobilization
1994 • 25 citations
Electrochemical immobilization of horseradish peroxidase on an electro-activated glassy carbon electrode
1996 • 24 citations
An enzyme electrode with response independent of the thickness of the enzyme layer
1996 • 23 citations
A new conducting polymer glucose sensor based on polythianaphthene
1995 • 20 citations
Physical study of film-forming acrylate emulsion polymers for biosensor applications
1997 • 19 citations
Flow-through tyrosinase enzyme reactor based on reticulated vitreous carbon functionalized by an electrochemically synthesized film
1996 • 13 citations