Back to search

Lactate Amperometric Biosensor Based on an Electrosynthesized Bilayer Film with Covalently Immobilized Enzyme

Data up to Jan 2025

Published1997
Citations68
References18

Total Citations Per Year

Abstract

References (18)

Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film

1990 • 561 citations

Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors

1990 • 343 citations

Correlation between Permselectivity and Chemical Structure of Overoxidized Polypyrrole Membranes Used in Electroproduced Enzyme Biosensors

1995 • 137 citations

Mediatorless electrocatalytic reduction of hydrogen peroxide at graphite electrodes chemically modified with peroxidases

1993 • 126 citations

Electrosynthesized Bilayer Polymeric Membrane for Effective Elimination of Electroactive Interferents in Amperometric Biosensors

1995 • 97 citations

Interference-free glucose sensor based on glucose-oxidase immobilized in an overoxidized non-conducting polypyrrole film

1992 • 96 citations

Amperometric tetrathiafulvalene-mediated lactate electrode using lactate oxidase absorbed on carbon foil

1990 • 75 citations

Electropolymerised o-phenylenediamine film as means of immobilising lactate oxidase for a L-lactate biosensor

1993 • 71 citations

Miniaturized flexible amperometric lactate probe

1993 • 66 citations

l-Lactate oxidase electrode based on methylene green and carbon paste

1993 • 63 citations

Electrochemical characterization of polypyrrole bienzyme electrodes with glucose oxidase and peroxidase

1993 • 58 citations

Immobilization of lactate oxidase in a poly(vinyl alcohol) matrix on platinized graphite electrodes by chemical cross-linking with isocyanate

1991 • 53 citations

A bienzyme modified carbon paste electrode for the amperometric detection of l-lactate at low potentials

1996 • 45 citations

Flow injection analysis of L-lactate with enzyme amplification and amperometric detection

1990 • 37 citations

Electrochemical immobilization of enzymes. Part VI. Microelectrodes for the detection of L-lactate based on flavocytochrome b 2 immobilized in a poly(phenol) film

1994 • 34 citations

Voltammetric and XPS Analysis of Metal‐Complexed Polytyramine Films : Geometry‐Dependent Electron Transfer Therein

1984 • 27 citations

Electrochemically prepared glucose biosensors: kinetic and faradaic processes involving ascorbic acid and role of the electropolymerized film in preventing electrode-fouling

1994 • 25 citations

Theoretical study of permselective layers on amperometric electrodes in flowing streams

1991 • 6 citations

Cited By (0)

Loading...
Lactate Amperometric Biosensor Based on an Electrosynthesized Bilayer Film with… (1997) – The Analyst | Metascience Observatory Explorer