Back to search

Enzyme-based biosensor as a selective detection unit in column liquid chromatography

Data up to Jan 2025

Published1994
Citations55
References44

Total Citations Per Year

Abstract

References (44)

ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY

1962 • 3,599 citations

The Enzyme Electrode

1967 • 1,250 citations

Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film

1990 • 561 citations

Chemically modified carbon paste electrodes in voltammetric analysis

1990 • 365 citations

Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors

1990 • 343 citations

Enzymatic determination of glucose in a flow system by catalytic oxidation of the nicotinamide coenzyme at a modified electrode

1985 • 274 citations

Enzyme microsensor for glucose with an electrochemically synthesized enzyme-polyaniline film

1988 • 228 citations

Selective detection in flow analysis based on the combination of immobilized enzymes and chemically modified electrodes

1991 • 224 citations

Amperometric biosensors based on an apparent direct electron transfer between electrodes and immobilized peroxidases. Plenary lecture

1992 • 223 citations

Chemically modified electrodes. Molecular design for electroanalysis

1987 • 206 citations

Strategies for the development of amperometric enzyme electrodes

1987 • 172 citations

A glucose electrode based on carbon paste chemically modified with a ferrocene-containing siloxane polymer and glucose oxidase, coated with a poly(ester-sulfonic acid) cation-exchanger

1990 • 169 citations

An electrochemical sensor for hydrogen peroxide based on peroxidase adsorbed on a spectrographic graphite electrode

1989 • 169 citations

Amperometric glucose sensors based on immobilized glucose-oxidizing enzymes and chemically modified electrodes

1991 • 155 citations

Biosensors: recent trends. A review

1992 • 138 citations

Electrical activity controlling system for a mediator-coexisting alcohol dehydrogenase-NAD conductive membrane

1990 • 137 citations

Mediatorless electrocatalytic reduction of hydrogen peroxide at graphite electrodes chemically modified with peroxidases

1993 • 126 citations

An amperometric glucose electrode based on carbon paste, chemically modified with glucose dehydrogenase, nicotinamide adenine dinucleotide, and a phenoxazine mediator, coated with a poly(ester sulfonic acid) cation exchanger

1991 • 125 citations

Organic phase enzyme electrodes

1991 • 120 citations

Chemically modified electrodes in liquid chromatography detection: A review

1991 • 115 citations

Mediatorless peroxidase electrode and preparation of bienzyme sensors

1990 • 109 citations

Reagentless chemically modified carbon paste electrode based on a phenothiazine polymer derivative and yeast alcohol dehydrogenase for the analysis of ethanol

1993 • 94 citations

Stabilization of analytical enzymes using a novel polymer–carbohydrate system and the production of a stabilized, single reagent for alcohol analysis

1992 • 73 citations

On-line immunochemical detection in liquid chromatography using fluorescein-labelled antibodies

1993 • 69 citations

Carbon fibres as electrode materials for the construction of peroxidase-modified amperometric biosensors

1993 • 66 citations

A review of reaction detection in HPLC

1987 • 64 citations

On-line fermentation process monitoring of carbohydrates and ethanol using tangential-flow filtration and column liquid chromatography

1993 • 62 citations

High-performance liquid chromatographic detection of L- and D-amino acids by use of immobilized enzyme electrodes as detectors

1988 • 60 citations

Principles and applications of electrochemical and optical biosensors

1991 • 58 citations

Flow injection analysis (FIA) based on enzymes or antibodies — applications in the life sciences

1990 • 49 citations

Monitoring molecules in the conscious brain by microdialysis

1992 • 41 citations

Determination of aflatoxin M1 using a dialysis-based immunoaffinity sample pretreatment system coupled online to liquid chromatography

1992 • 41 citations

A study of the use of microdialysis probes as a sampling unit in on-line bioprocess monitoring in conjunction with column liquid chromatography

1993 • 36 citations

Post-column derivatization in liquid chromatography using immobilized enzyme reactors and amperometric detection

1990 • 35 citations

Column Liquid Chromatography in combination with immobilized enzymes and electrochemical detection and its applications in some industrial processes

1992 • 23 citations

A flow-injection system using immobilized peroxidase and chromogenic reagents for possible determination of hydrogen peroxide

1985 • 23 citations

Liquid chromatographic separation and stereoselective detection of l- and d-amino acids with catalytic reaction detection using immobilized enzymes

1990 • 21 citations

Application of microbiological sensors in fermentation processes

1988 • 19 citations

Combined high-performance aqueous size-exclusion chromatographic and pyrolysis—gas chromatographic—mass spectrometric study of lignosulphonates in pulp mill effluents

1993 • 17 citations

Enzyme based detection systems in column liquid chromatography — Extension of selectivity and sensitivity

1993 • 13 citations

Evaluation of gel permeation chromatographic techniques and diode-array UV detection for the characterization of biotechnological fermentation substrates and broths

1992 • 9 citations

Silica based, solid phase reagents for derivatizations in chromatography

1992 • 7 citations

Coupled Enzyme Reactions in Flow Injection Analysis and Liquid Chromatography

1992 • 6 citations

Coupled Enzyme Reactions in Flow Injection Analysis and Liquid Chromatography

1992 • 4 citations

Cited By (0)

Loading...