Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors
Data up to Jan 2025
Total Citations Per Year
Abstract
References (42)
A Rapid and Sensitive Method for the Quantitation of Microgram Quantities of Protein Utilizing the Principle of Protein-Dye Binding
1976 • 225,752 citations
Dictionary of Organic Compounds
1943 • 1,058 citations
Chemical Cross-Linking: Reagents and Problems in Studies of Membrane Structure
1977 • 604 citations
Stabilization of Enzymes against Thermal Inactivation
1983 • 458 citations
Catalysis of electrode processes by multiply-charged metal complexes electrostatically bound to polyelectrolyte coatings on graphite electrodes, and the use of polymer-coated rotating disk electrodes in diagnosing kinetic and conduction mechanisms
1980 • 323 citations
WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR
1982 • 296 citations
Electrochemical polymerization of aromatic amines
1980 • 243 citations
Reticulated vitreous carbon—a new versatile electrode material
1981 • 241 citations
Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood
1988 • 230 citations
Permselectivity of films prepared by electrochemical oxidation of phenol and amino-aromatic compounds
1983 • 219 citations
Electroanalysis with chemically modified electrodes
1985 • 191 citations
Polaromicrotribometric study of polyphenylene oxide film formation on metal electrodes by electrolysis of disubstituted phenols
1977 • 182 citations
Determination of glucose in blood by flow injection analysis and an immobilized glucose oxidase column
1985 • 172 citations
Structure-stability relationships in proteins: new approaches to stabilizing enzymes
1984 • 169 citations
Thin-layer electrochemical detector with a glassy carbon electrode coated with a base-hydrolyzed cellulosic film
1985 • 168 citations
Polymer film chemically modified electrode as a potentiometric sensor
1980 • 165 citations
Surface-modified electrochemical detector for liquid chromatography
1983 • 133 citations
Polymer Films on Electrodes: 13. Incorporation of Catalysts into Electronically Conductive Polymers: Iron Phthalocyanine in Polypyrrole
1983 • 131 citations
Permselectivity and ion-exchange properties of Eastman-AQ polymers on glassy carbon electrodes
1989 • 123 citations
Cobalt phthalocyanine/cellulose acetate chemically modified electrodes for electrochemical detection in flowing streams. Multifunctional operation based upon the coupling of electrocatalysis and permselectivity
1988 • 118 citations
Facile attachment of transition metal complexes to graphite electrodes coated with polymeric ligands. Observation and control of metal-ligand coordination among reactants confined to electrode surfaces
1979 • 112 citations
Obtaining thin films of “reactive polymers” on metal surfaces by electrochemical polymerization part I. Reactivity of functional groups in a carbonyl substituted polyphenylene oxide film
1978 • 105 citations
Selectivity and sensitivity improvements at perfluorinated ionomer/cellulose acetate bilayer electrodes
1986 • 95 citations
Electrochemically polymerized N,N-dimethylaniline film with ion-exchange properties as an electrode modifier
1985 • 95 citations
pH response of platinum and vitreous carbon electrodes modified by electropolymerized films
1983 • 93 citations
Chemically modified electrodes
1978 • 93 citations
Properties of an insoluble form of trypsin
1971 • 71 citations
Reticulated vitreous carbon flow-through electrodes
1979 • 69 citations
Multiple-use polymer-modified electrodes for electroanalysis of metal ions in solution
1985 • 55 citations
Permselectivity of films prepared by electropolymerization of 2,6-dimethylphenol
1987 • 45 citations
Stability of enzymes.
1985 • 42 citations
Determination of enantiomer-labeled amino acids in small volumes of blood by gas chromatography
1982 • 41 citations
Approaches to enzyme stabilization
1983 • 39 citations
Chemically modified reticulated vitreous carbon electrode with immobilized enzyme as a detector in flow-injection determination of glucose
1984 • 39 citations
Amperometric determination of glucose in blood serum with a chemically modified enzyme membrane electrode in a continuous flow system
1983 • 33 citations
Flow injection analysis for glucose by the combined use of an immobilized glucose oxidase reactor and a peroxidase electrode
1984 • 29 citations
The Spectroelectrochemical Study of the Oxidation of 1,2‐Diaminobenzene: Alone and in the Presence of Ni(II)
1976 • 28 citations
Amperometric determination of phospholipids in blood serum with a lecithin-sensitive electrode in a flow injection system
1983 • 19 citations
Understanding enzyme stabilization
1984 • 17 citations
Metal substrate effects on pH response of tetracyanoquinodimethane modified electrodes
1984 • 16 citations
Stabilization of Subunit Enzymes by Intramolecular Crosslinking with Bifunctional Reagents
1984 • 11 citations
The use of synthetic polymers for preventing enzyme thermal inactivation: Some comments on the paper by Alfani and coworkers
1985 • 3 citations