The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring.
Data up to Jan 2025
Total Citations Per Year
Abstract
References (24)
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
1986 • 45,881 citations
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
1970 • 1,982 citations
Optimal thresholds, sensitivity, and specificity of long-term pH-metry for the detection of gastroesophageal reflux disease
1987 • 237 citations
An Integrated Field-Effect Electrode for Biopotential Recording
1974 • 229 citations
Long-term ambulatory gastric pH monitoring: Validation of a new method and effect of H2-antagonists
1985 • 212 citations
Cleaning and disinfection of equipment for gastrointestinal flexible endoscopy: interim recommendations of a Working Party of the British Society of Gastroenterology.
1988 • 170 citations
Technical aspects of intraluminal pH-metry in man: current status and recommendations.
1987 • 169 citations
Design of neutral hydrogen ion carriers for solvent polymeric membrane electrodes of selected pH range
1986 • 134 citations
Chemically Sensitive Field Effect Transistors
1980 • 118 citations
Comparison of gastric body and antral pH: a 24 hour ambulatory study in healthy volunteers.
1989 • 100 citations
Day-to-day variation of 24-hour intragastric acidity
1988 • 80 citations
Acidity at different sites in the proximal duodenum of normal subjects and patients with duodenal ulcer.
1966 • 78 citations
Electrodes for 24 hours pH monitoring--a comparative study.
1987 • 77 citations
Implantable sensors for closed-loop prosthetic systems
1985 • 52 citations
In vivo experiments with a pH-ISFET electrode
1984 • 44 citations
Early dinner reduces nocturnal gastric acidity.
1989 • 43 citations
On the use of monocrystalline antimony pH electrodes in gastro-oesophageal functional disorders
1982 • 38 citations
Identical 24-Hour Gastric pH Profiles When Using Intragastric Antimony or Glass Electrodes or Aspirated Gastric Juice
1988 • 34 citations
Duodenal bulb pH in normal subjects
1983 • 23 citations
Solvent polymeric membrane pH catheter electrode for intraluminal measurements in the upper gastrointestinal tract
1987 • 18 citations
Plastic pH electrodes for the measurement of gastrointestinal pH.
1985 • 16 citations
Regional difference in ambient intraluminal gastric acidity after cimetidine monitored by intragastric pH-metry.
1983 • 8 citations
In-vivo investigations by continuous measurements of gastric and duodenal pH.
1982 • 4 citations
C-MOS Compatible pH-ISFET with Al2O3 Gate in Implantable Sensors for Closed-Loop Prosthetic Systems
1985 • 3 citations