Back to search

Frontiers in elemental analysis by mass spectrometry

Data up to Jan 2025

Published1991
Citations30
References45

Total Citations Per Year

Abstract

References (45)

Studies of alkaline earth and transition metal M++ gas phase ion chemistry

1990 • 329 citations

Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry

1988 • 255 citations

Ion-molecule clusters involving doubly charged metal ions (M2+)

1990 • 233 citations

Inductively coupled plasma mass spectrometric detection for multielement flow injection analysis and elemental speciation by reversed-phase liquid chromatography

1986 • 209 citations

Multielement detection limits and sample nebulization efficiencies of an improved ultrasonic nebulizer and a conventional pneumatic nebulizer in inductively coupled plasma-atomic emission spectrometry

1977 • 207 citations

Production and study in the gas phase of multiply charged solvated or coordinated metal ions

1990 • 191 citations

A Study of Internal Standardization in Inductively Coupled Plasma-Mass Spectrometry

1987 • 178 citations

Identification and quantitation of arsenic species in a dogfish muscle reference material for trace elements

1988 • 167 citations

First studies of the gas phase ion chemistry of M3+ metal ion ligands

1990 • 166 citations

Direct injection nebulization for inductively coupled plasma mass spectrometry

1991 • 155 citations

Direct liquid sample introduction for flow injection analysis and liquid chromatography with inductively coupled, argon plasma spectrometric detection

1984 • 149 citations

Ultrasonic nebulization of liquid samples for analytical inductively coupled plasma-atomic spectroscopy: an update

1986 • 134 citations

Ion sampling for inductively coupled plasma mass spectrometry

1985 • 132 citations

A comparison of argon and mixed gas plasmas for inductively coupled plasma-mass spectrometry

1990 • 127 citations

Speciation of arsenic in urine using high-performance liquid chromatography with inductively coupled plasma mass spectrometric detection

1989 • 125 citations

Communication. Inductively coupled plasma as an ion source for high-resolution mass spectrometry

1989 • 120 citations

Inductively Coupled Plasma-Mass Spectrometry

2022 • 119 citations

Effect of Low Zinc Intake on Absorption and Excretion of Zinc by Infants Studied with 70Zn as Extrinsic Tag

1989 • 97 citations

Alleviation of overlap interferences for determination of potassium isotope ratios by inductively coupled plasma mass spectrometry

1988 • 92 citations

Measurements of total lead concentrations and of lead isotope ratios in whole blood by use of inductively coupled plasma source mass spectrometry

1988 • 79 citations

Direct laboratory determination of the 187Re half-life

1986 • 79 citations

Investigations on mixed-gas plasmas produced by adding nitrogen to the plasma gas in ICP-MS

1991 • 76 citations

Use of aerosol processing and nitrogen-argon plasmas for reduction of oxide interference in inductively coupled plasma mass spectrometry

1990 • 69 citations

Inductively coupled plasma mass spectrometric determination of lead isotopes

1987 • 66 citations

Identification of potential environmental sources of childhood lead poisoning by inductively coupled plasma mass spectrometry. Verification and case studies

1990 • 64 citations

Inductively coupled plasma mass spectrometric determination of the absorption of iron in normal women

1989 • 62 citations

Comparison of pneumatic nebulization and hydride generation inductively coupled plasma mass spectrometry for isotopic analysis of selenium

1989 • 60 citations

Accurate and precise determination of lead isotope ratios in clinical and environmental samples using inductively coupled plasma source mass spectrometry

1989 • 56 citations

Argon-xenon plasma for alleviating polyatomic ion interferences in inductively coupled plasma mass spectrometry

1991 • 49 citations

Zinc absorption in women: comparison of intrinsic and extrinsic stable-isotope labels

1991 • 47 citations

Measurements of Aerosol Particle Sizes from a Direct Injection Nebulizer

1991 • 47 citations

New method for the measurement of osmium isotopes applied to a New Zealand Cretaceous/Tertiary boundary shale

1986 • 47 citations

Intrinsic and Extrinsic Stable Isotopic Zinc Absorption by Infants from Formulas

1989 • 47 citations

High Resolution Mass Spectrometry with Inductively Coupled Argon Plasma Ionization Source

1989 • 41 citations

Effects of sampler-skimmer separation in inductively coupled plasma-mass spectrometry

1990 • 41 citations

Effect of ion-lens tuning and flow injection on non-spectroscopic matrix interferences in inductively coupled plasma mass spectrometry

1990 • 28 citations

Langmuir probe measurements of electron temperature and electron density behind the skimmer of an inductively coupled plasma mass spectrometer

1991 • 25 citations

Atmospheric pressure chemical ionization and ion‐spray mass spectrometry of some organotin species

1988 • 24 citations

Structural information from OH stretching frequencies—conformations of cyclohexanol and cyclohexandiols

1989 • 17 citations

Ion association by time-of-flight mass spectrometry

1989 • 17 citations

Conversion of an ultrasonic humidifier to a continuous-type ultrasonic nebulizer for atomic spectrometry

1990 • 17 citations

The spectroscopy of molecular ions

1989 • 15 citations

Intracavity absorption of He  Ne laser radiation as a direct time-resolved probe of R + NO ← RNO reaction kinetics (R = C3F7, CF3, CH3)

1990 • 13 citations

Alleviation of polyatomic ion interferences for determination of chlorine isotope ratios by inductively coupled plasma mass spectrometry

1990 • 7 citations

Ion association by time-of-flight mass spectrometry: a study of V-P-O catalysts

1990 • 4 citations

Cited By (0)

Loading...