Computerized tomography with X-ray, emission, and ultrasound sources
Data up to Jan 2025
Total Citations Per Year
Abstract
References (103)
Computerized transverse axial scanning (tomography): Part 1. Description of system
1973 • 3,736 citations
The Fourier reconstruction of a head section
1974 • 2,119 citations
Energy-selective reconstructions in X-ray computerised tomography
1976 • 1,864 citations
Representation of a Function by Its Line Integrals, with Some Radiological Applications
1963 • 1,358 citations
Reconstruction of Three Dimensional Structures from Electron Micrographs
1968 • 1,297 citations
A Method for Attenuation Correction in Radionuclide Computed Tomography
1978 • 1,273 citations
DIGITAL PROCESSING OF SIGNALS
1969 • 960 citations
Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier Transforms
1971 • 955 citations
Principles of computer assisted tomography (CAT) in radiographic and radioisotopic imaging
1976 • 719 citations
Strip Integration in Radio Astronomy
1956 • 667 citations
Inversion of Fan-Beam Scans in Radio Astronomy
1967 • 614 citations
Beam hardening in X-ray reconstructive tomography
1976 • 560 citations
Representation of a Function by Its Line Integrals, with Some Radiological Applications. II
1964 • 558 citations
Image Separation Radioisotope Scanning
1963 • 406 citations
Plane waves and spherical means applied to partial differential equations
1983 • 389 citations
A Quantitative Theory of the Hounsfield Unit and Its Application to Dual Energy Scanning
1977 • 320 citations
Image Reconstruction from Projections
1979 • 316 citations
Photon attenuation in computed tomography
1975 • 282 citations
A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
1978 • 272 citations
ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals
1977 • 249 citations
The Use of Positron-emitting Radioisotopes for the Localization of Brain Tumors
1951 • 228 citations
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
1977 • 201 citations
Statistical limitations in x‐ray reconstructive tomography
1976 • 199 citations
The noise power spectrum in computed X-ray tomography
1978 • 197 citations
Introduction to computer aided tomography
1978 • 182 citations
Emission computed tomography
1977 • 178 citations
Noise Due to Photon Counting Statistics in Computed X-Ray Tomography
1977 • 175 citations
Signal Processing of Broadband Pulsed Ultrasound: Measurement of Attenuation of Soft Biological Tissues
1978 • 166 citations
Algebraic Reconstruction of Spatial Distributions of Acoustic Velocities in Tissue from Their Time-of-Flight Profiles
1975 • 155 citations
Algebraic Reconstruction of Spatial Distributions of Acoustic Absorption within Tissue from Their Two-Dimensional Acoustic Projections
1974 • 155 citations
Design and performance characteristics of a whole-body positron transaxial tomograph.
1976 • 154 citations
Ultrasonic Reflectivity Tomography: Reconstruction with Circular Transducer Arrays
1979 • 150 citations
Isolated Flying Spot Detection of Radiodensity Dis-Continuities-Displaying the Internal Structural Pattern of a Complex Object
1961 • 149 citations
Attenuation Coefficients of Various Body Tissues, Fluids, and Lesions at Photon Energies of 18 to 136 keV
1975 • 140 citations
Three-dimensional density reconstruction from a series of two-dimensional projections
1972 • 140 citations
Fast Image Reconstruction Based on a Radon Inversion Formula Appropriate for Rapidly Collected Data
1977 • 128 citations
Dynamic Positron Emission Tomography for Study of Cerebral Hemodynamics in a Cross Section of the Head Using Positron-Emitting 68Ga-EDTA and 77Kr
1977 • 121 citations
Reconstruction of Ultrasound Propagation Speed Distributions in Soft Tissue: Time-Of-Flight Tomography
1977 • 108 citations
Statistical limitations in transaxial tomography
1976 • 105 citations
Attenuation Correction and Incomplete Projection in Single Photon Emission Computed Tomography
1979 • 103 citations
Design Considerations for a Positron Emission Transverse Tomograph (PETT V) for Imaging of the Brain
1978 • 102 citations
An Evaluation of the Quantitative and Radiation Features of a Scanning X-Ray Transverse Axial Tomograph: The EMI Scanner
1974 • 98 citations
Density reconstruction using arbitrary ray-sampling schemes
1978 • 92 citations
A Computer Assisted Ringdector Positron Camera System for Reconstruction Tomography of the Brain
1978 • 84 citations
Calculation of Refractive Index Distribution from Interferograms Using the Born and Rytov's Approximation
1975 • 82 citations
High Resolution Computed Tomography of Positron Emitters
1977 • 81 citations
Three-dimensional imaging in the positron camera using Fourier techniques
1977 • 78 citations
Correction for beam hardening in computed tomography
1978 • 78 citations
A Multislice Positron Emission Computed Tomograph (PETT IV) Yielding Transverse and Longitudinal Images
1978 • 76 citations
Reconstruction Tomography in Diagnostic Radiology and Nuclear Medicine
1977 • 76 citations
Polychromatic Streak Artifacts in Computed Tomography Images
1978 • 75 citations
Experimental Study of the Photon Energy Spectrum of Primary Diagnostic X-Rays
1966 • 73 citations
A New Approach to Interpolation in Computed Tomography
1978 • 69 citations
Computed Tomography with Fan Beam Geometry
1977 • 67 citations
Correction for spectral artifacts in cross‐sectional reconstruction from x rays
1977 • 65 citations
Convolution reconstruction of fan beam projections
1976 • 64 citations
The interpretation of optical projections
1970 • 64 citations
Imaging soft tissue through bone with ultrasound transmission tomography by reconstruction
1977 • 62 citations
Basic principles of computed axial tomography
1977 • 60 citations
Reconstruction of Three-Dimensional Velocity Fields and Other Parameters by Acoustic Ray Tracing
1975 • 59 citations
Correction functions for optimizing the reconstructed image in transverse section scan
1975 • 59 citations
The Apical Artifact
1978 • 59 citations
Quantitative Interpretation of Three-Dimensional Weakly Refractive Phase Objects Using Holographic Interferometry
1969 • 58 citations
Split-Detector Computed Tomography: A Preliminary Report
1978 • 57 citations
Ultrasonic attenuation tomography of soft tissues
1979 • 54 citations
Ultrasonics in medicine and biology
1977 • 53 citations
ART and the ribosome: A preliminary report on the three-dimensional structure of individual ribosomes determined by an algebraic reconstruction technique
1970 • 52 citations
Resolution in ART
1971 • 46 citations
The Peripheral Zone of Increased Density in Cranial Computed Tomography
1975 • 42 citations
Spectral effects on three-dimensional reconstruction from x rays
1975 • 40 citations
Performance and Evaluation of the Circular Ring Transverse Axial Positron Camera (CRTAPC)
1977 • 40 citations
The Physical Aspects of Diagnostic Radiology
1967 • 37 citations
Determination of effective energies in CT calibration
1978 • 35 citations
Computerized Tomography Using Video Recorded Fluoroscopic Images
1977 • 35 citations
Noise Limitations in X-Ray Computed Tomography
1978 • 31 citations
On Methods of Three-Dimensional Reconstruction from a Set of Radioisotope Scintigrams
1976 • 31 citations
Slice Geometry in Computer Assisted Tomography
1977 • 30 citations
Correction for Collimator Width (Restoration) in Reconstructive X-Ray Tomography
1977 • 30 citations
Three-dimensional reconstruction of isotope distributions
1974 • 27 citations
Cross-Section Reconstruction with a Fan-Beam Scanning Geometry
1977 • 24 citations
Xenon Ionization Detectors for Fan Beam Computed Tomography Scanners
1977 • 22 citations
Breast Imaging by Ultrasonic Computer-Assisted Tomography
1980 • 20 citations
Design and Performance Characteristics of a Production Model Positron Imaging System
1978 • 20 citations
Analysis of a Cylindrical Hybrid Positron Camera with Bismuth Germanate (BGO) Scintillation Crystals
1978 • 20 citations
An improved image algorithm for CT scanners
1978 • 17 citations
The Capability of Fluoroscopic Systems for the Production of Computerized Axial Tomograms
1976 • 16 citations
Positron Ring Cameras for Emission-Computed Tomography
1977 • 16 citations
Ultrasound Transaxial Tomography by Reconstruction
1976 • 15 citations
MEASUREMENT AND RECONSTRUCTION OF ULTRASONIC PARAMETERS FOR DIAGNOSTIC IMAGING.
1976 • 15 citations
PETT IV: Design Analysis and Performance Characteristics
1978 • 15 citations
Computed Transaxial Imaging Using Single Gamma Emitters
1978 • 13 citations
More accurate interpolation using discrete Fourier transforms
1978 • 12 citations
<title>A Comparison Of The Number Of Rays Vs The Number Of Views In Reconstruction Tomography</title>
1977 • 11 citations
Three-Dimensional Reconstruction in Planar Positron Cameras Using Fourier Deconvolution of Generalized Tomograms
1978 • 9 citations
Computerized Tomograpy Using Video Techniques
1977 • 8 citations
Transverse Section Imaging with Carbon-11 Labeled Carbon Monoxide
1978 • 7 citations
<title>A Physical Comparison of a Fluoroscopic CAT System and the EMI Head Scanner</title>
1976 • 6 citations
<title>Noise And Dose In Energy Dependent Computerized Tomography</title>
1976 • 6 citations
The Fundamentals of Radiological Science
1975 • 5 citations
<title>Interpolation Problems in Image Reconstruction</title>
1976 • 4 citations
A simple absorption correction in positron (annihilation gamma coincidence detection) transverse axial tomography
1976 • 4 citations
Initial Investigation of Computed Tomography for Breast Imaging with Focused Ultrasound Beams
1978 • 4 citations
<title>The Effect Of Noise In The Projection Data On The Reconstruction Produced by Computerized Tomography</title>
1976 • 3 citations
Cited By (0)
No citing papers found in database