Back to search

Matrix modifier and L'vov platform for elimination of matrix interferences in the analysis of fish tissues for lead by graphite furnace atomic absorption spectrometry

Data up to Jan 2025

Published1982
Citations30
References27

Total Citations Per Year

Abstract

References (27)

Electrothermal atomization—the way toward absolute methods of atomic absorption analysis

1978 • 443 citations

Selection and cleaning of plastic containers for storage of trace element samples

1977 • 381 citations

Reduction of matrix interferences for lead determination with the L'vov platform and the graphite furnace

1979 • 139 citations

Variables in the determination of mercury by cold vapor atomic absorption

1976 • 136 citations

A kinetic theory of atomisation for non-flame atomic-absorption spectrometry with a graphite furnace. The kinetics and mechanism of atomisation for copper

1974 • 118 citations

Interference effects in furnace atomic absorption spectrometry

1978 • 103 citations

Tantalum treated graphite atomizer tubes for atomic absorption spectrometry

1978 • 101 citations

Determination of lead in a chloride matrix with the graphite furnace

1978 • 92 citations

Background correction in atomic absorption utilizing the Zeeman effect

1980 • 79 citations

Communication. A novel approach to the elimination of matrix interferences in flameless atomic-absorption spectroscopy using a graphite furnace

1976 • 76 citations

Sampling at constant temperature in graphite furnace atomic absorption spectrometry

1979 • 71 citations

Reduction of matrix interferences in furnace atomic absorption with the L'vov Platform

1981 • 59 citations

Investigations of reactions involved in flameless atomic absorption procedures

1977 • 57 citations

Removal of trace elemental impurities from polyethylene by nitric acid

1975 • 56 citations

Mechanism of atom loss in graphite furnace atomic absorption spectrometry

1977 • 53 citations

Communication. Observations on the direct determination of lead in complex matrices by carbon furnace atomic-absorption spectrophotometry

1977 • 50 citations

Theory of Zeeman atomic absorption spectrometry

1978 • 45 citations

Application of the inverse Zeeman effect to background correction in electrothermal atomic-absorption analysis

1977 • 39 citations

Application of a modulated magnetic field to a graphite furnace in Zeeman effect atomic absorption spectrometry

1980 • 31 citations

Carbide coating process for graphite tubes in electrothermal atomic absorption spectrometry

1979 • 29 citations

Influence of ascorbic acid on the matrix interferences observed during the carbon furnace atomic-absorption spectrophotometric determination of lead in some drinking waters

1978 • 27 citations

The Shape of Analytical Curves in Zeeman Atomic Absorption Spectroscopy. II. Theoretical Analysis and Experimental Evidence for Absorption Maximum in the Analytical Curve

1980 • 24 citations

Determination of lead and cadmium in fish and clam tissue by atomic absorption spectrometry with a molybdenum and lanthanum treated pyrolytic graphite atomizer

1980 • 24 citations

The Shape of Analytical Curves in Zeeman Atomic Absorption Spectroscopy. I. Normal Concentration Range

1979 • 23 citations

Zeeman effect in flame atomic absorption spectrometry

1980 • 18 citations

Polarized Zeeman effect atomic absorption spectrophotometry using a flame atomizer

1981 • 14 citations

Anwendbarkeit der Zeeman-Effekt/Atomabsorption in der Komplexchemie und Spurenanalyse

1980 • 6 citations

Cited By (0)

Loading...