Back to search

Ambient ionization mass spectrometry: current understanding of mechanistic theory; analytical performance and application areas

Data up to Jan 2025

Published2010
Citations350
References131

Total Citations Per Year

Abstract

References (131)

Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry

1988 • 3,058 citations

Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions

2005 • 2,336 citations

Electrospray ion source. Another variation on the free-jet theme

1984 • 1,991 citations

Ambient Mass Spectrometry

2006 • 1,367 citations

Ambient mass spectrometry using desorption electrospray ionization (DESI): instrumentation, mechanisms and applications in forensics, chemistry, and biology

2005 • 830 citations

Laser Ablation Electrospray Ionization for Atmospheric Pressure, in Vivo, and Imaging Mass Spectrometry

2007 • 767 citations

Low-Temperature Plasma Probe for Ambient Desorption Ionization

2008 • 677 citations

A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry

2000 • 638 citations

Proceedings of the 46th ASMS Conference on Mass Spectrometry and Allied Topics

1998 • 573 citations

Analysis of Solids, Liquids, and Biological Tissues Using Solids Probe Introduction at Atmospheric Pressure on Commercial LC/MS Instruments

2005 • 561 citations

Ambient desorption ionization mass spectrometry

2008 • 539 citations

Extractive electrospray ionization for direct analysis of undiluted urine, milk and other complex mixtures without sample preparation

2006 • 491 citations

Desorption electrospray ionization mass spectrometry: Imaging drugs and metabolites in tissues

2008 • 439 citations

Development of a dielectric barrier discharge ion source for ambient mass spectrometry

2007 • 431 citations

Direct, trace level detection of explosives on ambient surfaces by desorption electrospray ionization mass spectrometry

2005 • 429 citations

Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

2000 • 396 citations

Desorption electrospray ionization and other ambient ionization methods: current progress and preview

2010 • 365 citations

Generation and detection of multiply-charged peptides and proteins by matrix-assisted laser desorption electrospray ionization (MALDESI) fourier transform ion cyclotron resonance mass spectrometry

2006 • 355 citations

Improvement of biological time-of-flight-secondary ion mass spectrometry imaging with a bismuth cluster ion source

2005 • 340 citations

Desorption Electrospray Ionization Mass Spectrometry for High-Throughput Analysis of Pharmaceutical Samples in the Ambient Environment

2005 • 333 citations

Desorption sonic spray ionization for (high) voltage‐free ambient mass spectrometry

2006 • 299 citations

Development of capabilities for imaging mass spectrometry under ambient conditions with desorption electrospray ionization (DESI)

2006 • 251 citations

Ambient mass spectrometry employing direct analysis in real time (DART) ion source for olive oil quality and authenticity assessment

2009 • 241 citations

Desorption Atmospheric Pressure Photoionization

2007 • 237 citations

What can we learn from ambient ionization techniques?

2009 • 237 citations

Thin-Layer Chromatography and Mass Spectrometry Coupled Using Desorption Electrospray Ionization

2005 • 233 citations

Recent developments in ambient ionization techniques for analytical mass spectrometry

2008 • 226 citations

Surface Analysis under Ambient Conditions Using Plasma-Assisted Desorption/Ionization Mass Spectrometry

2007 • 223 citations

Direct Analysis of Pharmaceutical Drug Formulations Using Ion Mobility Spectrometry/Quadrupole-Time-of-Flight Mass Spectrometry Combined with Desorption Electrospray Ionization

2005 • 222 citations

Characterization of Solid Counterfeit Drug Samples by Desorption Electrospray Ionization and Direct‐analysis‐in‐real‐time Coupled to Time‐of‐flight Mass Spectrometry

2006 • 208 citations

Rapid in situ detection of alkaloids in plant tissue under ambient conditions using desorption electrospray ionization

2005 • 207 citations

Simulated splashes: Elucidating the mechanism of desorption electrospray ionization mass spectrometry

2008 • 203 citations

Mechanisms in molecular SIMS

1987 • 201 citations

Bioanalysis without Sample Cleanup or Chromatography: The Evaluation and Initial Implementation of Direct Analysis in Real Time Ionization Mass Spectrometry for the Quantification of Drugs in Biological Matrixes

2008 • 200 citations

The use of recently described ionisation techniques for the rapid analysis of some common drugs and samples of biological origin

2006 • 197 citations

Atmospheric Pressure Chemical Ionization Source. 2. Desorption−Ionization for the Direct Analysis of Solid Compounds

2008 • 195 citations

Forensic analysis of inks by imaging desorption electrospray ionization (DESI) mass spectrometry

2007 • 193 citations

Direct detection of explosives on solid surfaces by low temperature plasma desorption mass spectrometry

2008 • 192 citations

In Situ Trace Detection of Peroxide Explosives by Desorption Electrospray Ionization and Desorption Atmospheric Pressure Chemical Ionization

2008 • 182 citations

Desorption electrospray ionization (DESI) mass spectrometry and tandem mass spectrometry (MS/MS) of phospholipids and sphingolipids: Ionization, adduct formation, and fragmentation

2008 • 173 citations

Easy Ambient Sonic-Spray Ionization-Membrane Interface Mass Spectrometry for Direct Analysis of Solution Constituents

2008 • 171 citations

Direct Analysis in Real Time for Reaction Monitoring in Drug Discovery

2007 • 167 citations

Quantitation of Chemical Warfare Agents Using the Direct Analysis in Real Time (DART) Technique

2009 • 166 citations

Validation of the Direct Analysis in Real Time Source for Use in Forensic Drug Screening

2009 • 165 citations

Neutral Desorption Sampling of Living Objects for Rapid Analysis by Extractive Electrospray Ionization Mass Spectrometry

2007 • 164 citations

Easy Ambient Sonic-Spray Ionization Mass Spectrometry Combined with Thin-Layer Chromatography

2008 • 162 citations

Ambient molecular imaging by desorption electrospray ionization mass spectrometry

2008 • 161 citations

Critical revision of GD-MS, LA-ICP-MS and SIMS as inorganic mass spectrometric techniques for direct solid analysis

2009 • 159 citations

Direct analysis of liquid samples by desorption electrospray ionization-mass spectrometry (DESI-MS)

2008 • 155 citations

Toward Plasma Proteome Profiling with Ion Mobility-Mass Spectrometry

2006 • 154 citations

High-throughput trace melamine analysis in complex mixtures

2008 • 153 citations

Determination of isopropylthioxanthone (ITX) in milk, yoghurt and fat by HPTLC-FLD, HPTLC-ESI/MS and HPTLC-DART/MS

2006 • 153 citations

Principal component analysis of urine metabolites detected by NMR and DESI–MS in patients with inborn errors of metabolism

2006 • 153 citations

cis-Diol functional group recognition by reactive desorption electrospray ionization (DESI)

2006 • 144 citations

Improved imaging resolution in desorption electrospray ionization mass spectrometry

2008 • 143 citations

Reactive Desorption Electrospray Ionization Linear Ion Trap Mass Spectrometry of Latest-Generation Counterfeit Antimalarials via Noncovalent Complex Formation

2007 • 140 citations

Desorption Electrospray Ionization-Mass Spectrometry of Proteins

2007 • 139 citations

Combining desorption electrospray ionization mass spectrometry and nuclear magnetic resonance for differential metabolomics without sample preparation

2006 • 139 citations

Ionization Mechanism of Positive-Ion Direct Analysis in Real Time: A Transient Microenvironment Concept

2009 • 130 citations

Ion/surface reactions and ion soft-landing

2005 • 130 citations

Rapid and Unambiguous Identification of Melamine in Contaminated Pet Food Based on Mass Spectrometry with Four Degrees of Confirmation

2007 • 129 citations

Ambient generation of fatty acid methyl ester ions from bacterial whole cells by direct analysis in real time (DART) mass spectrometry

2006 • 127 citations

Coupling Desorption Electrospray Ionization with Ion Mobility/Mass Spectrometry for Analysis of Protein Structure: Evidence for Desorption of Folded and Denatured States

2006 • 125 citations

Direct analysis of Stevia leaves for diterpene glycosides by desorption electrospray ionization mass spectrometry

2009 • 125 citations

Infrared laser-assisted desorption electrospray ionization mass spectrometry

2007 • 123 citations

Neutral desorption sampling coupled to extractive electrospray ionization mass spectrometry for rapid differentiation of biosamples by metabolomic fingerprinting

2007 • 122 citations

Quantification of small molecules in plasma with direct analysis in real time tandem mass spectrometry, without sample preparation and liquid chromatographic separation

2008 • 118 citations

Laser Ablation Coupled to a Flowing Atmospheric Pressure Afterglow for Ambient Mass Spectral Imaging

2008 • 117 citations

Detection of explosives on skin using ambient ionization mass spectrometry

2007 • 117 citations

Non-Proximate Detection of Small and Large Molecules by Desorption Electrospray Ionization and Desorption Atmospheric Pressure Chemical Ionization Mass Spectrometry: Instrumentation and Applications in Forensics, Chemistry, and Biology

2007 • 111 citations

High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry

2008 • 110 citations

High-Throughput Cytochrome P450 Inhibition Assays Using Laser Diode Thermal Desorption-Atmospheric Pressure Chemical Ionization-Tandem Mass Spectrometry

2007 • 108 citations

Differentiation of Maturity and Quality of Fruit Using Noninvasive Extractive Electrospray Ionization Quadrupole Time-of-Flight Mass Spectrometry

2007 • 106 citations

Fabric analysis by ambient mass spectrometry for explosives and drugs

2008 • 105 citations

Neutral desorption sampling of biological surfaces for rapid chemical characterization by extractive electrospray ionization mass spectrometry

2008 • 100 citations

Simulations and Experimental Investigation of Atmospheric Transport in an Ambient Metastable-Induced Chemical Ionization Source

2008 • 100 citations

Combining Two-Dimensional Diffusion-Ordered Nuclear Magnetic Resonance Spectroscopy, Imaging Desorption Electrospray Ionization Mass Spectrometry, and Direct Analysis in Real-Time Mass Spectrometry for the Integral Investigation of Counterfeit Pharmaceuticals

2009 • 99 citations

New surfaces for desorption electrospray ionization mass spectrometry: porous silicon and ultra‐thin layer chromatography plates

2006 • 98 citations

Ionization mechanisms related to negative Ion APPI, APCI, and DART

2009 • 98 citations

Implementation of DART and DESI ionization on a fieldable mass spectrometer

2008 • 97 citations

Salt tolerance of desorption electrospray ionization (DESI)

2007 • 96 citations

Characterization of the chemical components on the surface of different solids with electrospray‐assisted laser desorption ionization mass spectrometry

2007 • 92 citations

Eliminating the Interferences from TRIS Buffer and SDS in Protein Analysis by Fused-Droplet Electrospray Ionization Mass Spectrometry

2005 • 91 citations

Thermal Production and Reactions of Organic Ions at Atmospheric Pressure

2006 • 91 citations

Desorption Electrospray Ionization in a Small Pressure-Tight Enclosure

2007 • 89 citations

Temperature‐dependent release of volatile organic compounds of eucalypts by direct analysis in real time (DART) mass spectrometry

2009 • 89 citations

Coupling desorption electrospray ionisation and neutral desorption/extractive electrospray ionisation with a travelling‐wave based ion mobility mass spectrometer for the analysis of drugs

2007 • 88 citations

Direct analysis of curcumin in turmeric by DART‐MS

2009 • 85 citations

Mass spectrometry of intact neutral macromolecules using intense non‐resonant femtosecond laser vaporization with electrospray post‐ionization

2009 • 83 citations

Charged residue versus ion evaporation for formation of alkali metal halide cluster ions in ESI

2000 • 81 citations

Matrix-Assisted Laser Desorption/Ionization Coupled with Quadrupole/Orthogonal Acceleration Time-of-Flight Mass Spectrometry for Protein Discovery, Identification, and Structural Analysis

2001 • 80 citations

On-line Coupling of Solid-Phase Extraction to Liquid Chromatography--A Review

2009 • 80 citations

High-Throughput Mode Liquid Microjunction Surface Sampling Probe

2009 • 77 citations

Desorption electrospray ionisation mass spectrometry and tandem mass spectrometry of low molecular weight synthetic polymers

2006 • 76 citations

Comparison between vacuum sublimed matrices and conventional dried droplet preparation in MALDI-TOF mass spectrometry

2009 • 74 citations

Rapid screening of active ingredients in drugs by mass spectrometry with low-temperature plasma probe

2009 • 74 citations

In vivo recognition of Bacillus subtilis by desorption electrospray ionization mass spectrometry (DESI-MS)

2009 • 74 citations

Desorption electrospray ionisation mass spectrometric analysis of chemical warfare agents from solid‐phase microextraction fibers

2007 • 73 citations

An improved thin‐layer chromatography/mass spectrometry coupling using a surface sampling probe electrospray ion trap system

2004 • 72 citations

Targeted metabolomic analysis of Escherichia coli by desorption electrospray ionization and extractive electrospray ionization mass spectrometry

2008 • 69 citations

Analysis of biodiesel and biodiesel–petrodiesel blends by high performance thin layer chromatography combined with easy ambient sonic-spray ionization mass spectrometry

2009 • 68 citations

Desorption due to charge exchange in low‐energy collisions of organofluorine ions at solid surfaces

1988 • 66 citations

MALDI Mass Spectrometry Imaging, from its Origins up to Today: The State of the Art

2009 • 65 citations

Recent developments in extraction procedures relevant to analytical toxicology

2007 • 65 citations

Reactive desorption electrospray ionization mass spectrometry (DESI-MS) of natural products of a marine alga

2009 • 65 citations

HPTLC/DESI‐MS imaging of tryptic protein digests separated in two dimensions

2008 • 63 citations

Desorption Electrospray/Metastable-Induced Ionization: A Flexible Multimode Ambient Ion Generation Technique

2009 • 61 citations

Peptide Fragmentation Assisted by Surfaces Treated with a Low‐Temperature Plasma in NanoESI

2008 • 60 citations

Collision‐induced fragmentation pathways including odd‐electron ion formation from desorption electrospray ionisation generated protonated and deprotonated drugs derived from tandem accurate mass spectrometry

2006 • 58 citations

Detection of Gamma‐Hydroxybutyric Acid in Various Drink Matrices via AccuTOF‐DART*

2009 • 54 citations

Detection of Attomole Amounts of Analyte by Desorption Electrospray Ionization Mass Spectrometry (DESI-MS) Determined Using Fluorescence Spectroscopy

2007 • 53 citations

Analysis of tryptic peptides using desorption electrospray ionisation combined with ion mobility spectrometry/mass spectrometry

2007 • 53 citations

Single-Shot Biodiesel Analysis: Nearly Instantaneous Typification and Quality Control Solely by Ambient Mass Spectrometry

2008 • 52 citations

HRMS Directly From TLC Slides. A Powerful Tool for Rapid Analysis of Organic Mixtures

2008 • 52 citations

Direct analysis of pharmaceutical formulations from non‐bonded reversed‐phase thin‐layer chromatography plates by desorption electrospray ionisation ion mobility mass spectrometry

2009 • 47 citations

Desorption electrospray ionization reactions between host crown ethers and the influenza neuraminidase inhibitor oseltamivir for the rapid screening of Tamiflu®

2008 • 42 citations

Molecular Ions and Protonated Molecules Observed in the Atmospheric Solids Analysis Probe Analysis of Steroids

2010 • 39 citations

Desorption Electrospray Ionization Tandem Mass Spectrometry for Detection of 24 Carcinogenic Aromatic Amines in Textiles

2009 • 36 citations

Ambient Aerodynamic Ionization Source for Remote Analyte Sampling and Mass Spectrometric Analysis

2008 • 32 citations

Carbohydrate and steroid analysis by desorption electrospray ionization mass spectrometry

2008 • 30 citations

Pharmaceutical cleaning validation using non‐proximate large‐area desorption electrospray ionization mass spectrometry

2008 • 30 citations

Direct quantification of organic acids in aerosols by desorption electrospray ionization mass spectrometry

2009 • 30 citations

Evaluation of a surface‐sampling probe electrospray mass spectrometry system for the analysis of surface‐deposited and affinity‐captured proteins

2006 • 30 citations

Fabric softeners: nearly instantaneous characterization and quality control of cationic surfactants by easy ambient sonic‐spray ionization mass spectrometry

2009 • 28 citations

Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionisation Mass Spectrometry: A Review

2005 • 27 citations

Desorption electrospray ionization mass spectrometry of DNA nucleobases: implications for a liquid film model

2009 • 23 citations

Development of a direct current He atmospheric-pressure glow discharge as an ionization source for elemental mass spectrometry via hydride generation

2006 • 22 citations

Direct Ambient Analysis of Pharmaceutical and Ecstasy Tablets

2006 • 17 citations

Aspects of the Role of Surfaces in Ionization Processes

2009 • 13 citations

“Soft” or “Hard” Ionisation? Investigation of Metastable Gas Temperature Effect on Direct Analysis in Real-Time Analysis of Voriconazole

2009 • 10 citations

Use of Single Particle Aerosol Mass Spectrometry for the Automated Nondestructive Identification of Drugs in Multicomponent Samples

2009 • 7 citations

Cited By (0)

Loading...