Back to search

Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field

Data up to Jan 2025

Published2004
Citations249
References27

Total Citations Per Year

Abstract

References (27)

Geant4—a simulation toolkit

2003 • 21,536 citations

MCNP-A General Monte Carlo N-Particle Transport Code

1993 • 5,155 citations

BEAM: A Monte Carlo code to simulate radiotherapy treatment units

1995 • 1,409 citations

The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy

2000 • 1,403 citations

Flat-panel cone-beam computed tomography for image-guided radiation therapy

2002 • 1,288 citations

Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapy

1993 • 1,041 citations

Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality

2000 • 925 citations

Accurate condensed history Monte Carlo simulation of electron transport. I. <scp>EGS</scp>nrc, the new <scp>EGS4</scp> version

2000 • 911 citations

The Physics of Radiation Therapy

2003 • 689 citations

Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor

2000 • 459 citations

Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report

2002 • 356 citations

INTERNATIONAL COMMISSION ON RADIATION UNITS AND MEASUREMENTS (ICRU)

1974 • 321 citations

Megavoltage CT on a tomotherapy system

1999 • 257 citations

A performance comparison of flat‐panel imager‐based MV and kV cone‐beam CT

2002 • 176 citations

Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy

2002 • 160 citations

Validation of<scp>GEANT4</scp>, an object-oriented Monte Carlo toolkit, for simulations in medical physics

2004 • 151 citations

Automatic three‐dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data

1996 • 146 citations

The effect of strong longitudinal magnetic fields on dose deposition from electron and photon beams

1993 • 110 citations

Directional dependence in film dosimetry: radiographic and radiochromic film

2001 • 90 citations

Feasibility of automatic marker detection with an a-Si flat-panel imager

2001 • 55 citations

Calculating photon beam characteristics with Monte Carlo techniques

1999 • 49 citations

An apparatus for applying strong longitudinal magnetic fields to clinical photon and electron beams

2001 • 39 citations

Magnetic fields with photon beams: Dose calculation using electron multiple-scattering theory

2000 • 31 citations

Magnetic fields with photon beams: Monte Carlo calculations for a model magnetic field

2000 • 25 citations

Electron beam therapy with transverse magnetic fields

1999 • 24 citations

Control of photon beam dose profiles by localized transverse magnetic fields

2000 • 22 citations

Characterization of a fluoroscopic imaging system for kV and MV radiography

2000 • 22 citations

Cited By (0)

No citing papers found in database

Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a… (2004) – Physics in Medicine and Biology | Metascience Observatory Explorer