WATER FITTINGS AS SOURCES OF LEGIONELLA PNEUMOPHILA IN A HOSPITAL PLUMBING SYSTEM
Data up to Jan 2025
Total Citations Per Year
Abstract
References (11)
Improved semiselective medium for isolation of Legionella pneumophila from contaminated clinical and environmental specimens
1981 • 500 citations
LEGIONELLACEAE IN THE HOSPITAL WATER-SUPPLY
1983 • 262 citations
LEGIONNAIRES' DISEASE IN A TRANSPLANT UNIT: ISOLATION OF THE CAUSATIVE AGENT FROM SHOWER BATHS
1980 • 249 citations
Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures
1982 • 209 citations
INVESTIGATION AND CONTROL OF AN OUTBREAK OF LEGIONNAIRES' DISEASE IN A DISTRICT GENERAL HOSPITAL
1981 • 147 citations
EXPERIMENTAL TRANSMISSION OF LEGIONNAIRES' DISEASE BY EXPOSURE TO AEROSOLS OF LEGIONELLA PNEUMOPHILA
1981 • 117 citations
LEGIONELLA PNEUMOPHILA IN WATER PLUMBING SYSTEMS
1982 • 87 citations
Survival of virulentLegionella pneumophilain aerosols
1983 • 75 citations
Legionnaires' disease: further evidence to implicate water storage and distribution systems as sources.
1981 • 54 citations
Dissolved Oxygen Utilization as an Indicator of Total Microbial Activity on Non‐metallic Materials in Contact with Potable Water
1979 • 21 citations
A simple disc technique for the presumptive identification of Legionella pneumophila
1982 • 6 citations