Electrocatalysis and flow-injection analysis of hydrogen peroxide at a chemically modified electrode
Data up to Jan 2025
Total Citations Per Year
Abstract
References (22)
Covalent linkage of glucose oxidase on modified glassy carbon electrodes. Kinetic phenomena
1980 • 200 citations
An electrochemical sensor for hydrogen peroxide based on peroxidase adsorbed on a spectrographic graphite electrode
1989 • 169 citations
Enzyme Electrodes Using Bioelectrocatalytic Reduction of Hydrogen Peroxide
1990 • 148 citations
Redox chemistry of dioxygen species
1979 • 142 citations
Electrocatalytic properties of bifunctional Pt/W(VI,V) oxide microstructures electrodeposited on carbon substrates
1989 • 130 citations
A carbon electrode sputtered with palladium and gold for the amperometric detection of hydrogen peroxide
1985 • 113 citations
Electrochemical studies of hydrogen peroxide at a platinum disc electrode
1981 • 94 citations
Catalysis of the electroreduction of hydrogen peroxide by montmorillonite clay coatings on graphite electrodes
1986 • 94 citations
Horseradish‐root‐modified carbon paste bioelectrode
1989 • 75 citations
Kinetics of oxygen reduction reactions involving catalytic decomposition of hydrogen peroxide
1978 • 74 citations
Voltammetric reduction and determination of hydrogen peroxide at an electrode modified with a film containing palladium and iridium
1989 • 65 citations
Flow‐injection analysis of hydrogen peroxide using a horseradish peroxidase‐modified electrode detection system
1990 • 60 citations
Electrocatalysis and flow detection at a glassy carbon electrode modified with a thin film of oxymanganese species
1991 • 57 citations
Chronopotentiometry of hydrogen peroxide with a platinum wire electrode
1963 • 54 citations
Peroxidase–ferrocene modified carbon paste electrode as an amperometric sensor for the hydrogen peroxide assay
1991 • 51 citations
A liver tissue-based electrochemical sensor for hydrogen peroxide
1982 • 40 citations
A glucose sensor based on the adsorption of glucose on a palladium/gold modified carbon electrode
1986 • 32 citations
Pineapple‐tissue based bioelectrode for the determination of hydrogen peroxide
1990 • 29 citations
Grape tissue-based electrochemical sensor for the determination of hydrogen peroxide
1990 • 22 citations
Mechanism of the mediated reduction of hydrogen peroxide at an electrode modified with a film containing a basic form of iridium oxide
1990 • 18 citations
Amperometric determination of hydrogen peroxide in pickling baths for copper and copper alloys by flow injection analysis
1983 • 18 citations
Biosensor for determination of hydrogen peroxide based on catalase activity of human erythrocytes
1990 • 10 citations