Back to search

Electrocatalysis and flow-injection analysis of hydrogen peroxide at a chemically modified electrode

Data up to Jan 2025

Published1992
Citations36
References22

Total Citations Per Year

Abstract

References (22)

Covalent linkage of glucose oxidase on modified glassy carbon electrodes. Kinetic phenomena

1980 • 200 citations

An electrochemical sensor for hydrogen peroxide based on peroxidase adsorbed on a spectrographic graphite electrode

1989 • 169 citations

Enzyme Electrodes Using Bioelectrocatalytic Reduction of Hydrogen Peroxide

1990 • 148 citations

Redox chemistry of dioxygen species

1979 • 142 citations

Electrocatalytic properties of bifunctional Pt/W(VI,V) oxide microstructures electrodeposited on carbon substrates

1989 • 130 citations

A carbon electrode sputtered with palladium and gold for the amperometric detection of hydrogen peroxide

1985 • 113 citations

Electrochemical studies of hydrogen peroxide at a platinum disc electrode

1981 • 94 citations

Catalysis of the electroreduction of hydrogen peroxide by montmorillonite clay coatings on graphite electrodes

1986 • 94 citations

Horseradish‐root‐modified carbon paste bioelectrode

1989 • 75 citations

Kinetics of oxygen reduction reactions involving catalytic decomposition of hydrogen peroxide

1978 • 74 citations

Voltammetric reduction and determination of hydrogen peroxide at an electrode modified with a film containing palladium and iridium

1989 • 65 citations

Flow‐injection analysis of hydrogen peroxide using a horseradish peroxidase‐modified electrode detection system

1990 • 60 citations

Electrocatalysis and flow detection at a glassy carbon electrode modified with a thin film of oxymanganese species

1991 • 57 citations

Chronopotentiometry of hydrogen peroxide with a platinum wire electrode

1963 • 54 citations

Peroxidase–ferrocene modified carbon paste electrode as an amperometric sensor for the hydrogen peroxide assay

1991 • 51 citations

A liver tissue-based electrochemical sensor for hydrogen peroxide

1982 • 40 citations

A glucose sensor based on the adsorption of glucose on a palladium/gold modified carbon electrode

1986 • 32 citations

Pineapple‐tissue based bioelectrode for the determination of hydrogen peroxide

1990 • 29 citations

Grape tissue-based electrochemical sensor for the determination of hydrogen peroxide

1990 • 22 citations

Mechanism of the mediated reduction of hydrogen peroxide at an electrode modified with a film containing a basic form of iridium oxide

1990 • 18 citations

Amperometric determination of hydrogen peroxide in pickling baths for copper and copper alloys by flow injection analysis

1983 • 18 citations

Biosensor for determination of hydrogen peroxide based on catalase activity of human erythrocytes

1990 • 10 citations

Cited By (0)

Loading...