A comparison of the efficacy and duration of action of candesartan cilexetil and losartan as assessed by clinic and ambulatory blood pressure after a missed dose, in truly hypertensive patients A placebo-controlled, forced titration study
Data up to Jan 2025
Total Citations Per Year
Abstract
References (19)
Angiotensin II receptors and angiotensin II receptor antagonists.
1993 • 1,843 citations
Ambulatory blood pressure. An independent predictor of prognosis in essential hypertension.
1994 • 1,687 citations
Pulse Pressure
1997 • 1,026 citations
Ambulatory Blood Pressure
1999 • 355 citations
A Randomized, Placebo-Controlled, Double-Blind, Parallel Study of Various Doses of Losartan Potassium Compared With Enalapril Maleate in Patients With Essential Hypertension
1995 • 223 citations
Effects of modulators of the renin???angiotensin???aldosterone system on cough
1994 • 217 citations
Pharmacological profile of a highly potent and long-acting angiotensin II receptor antagonist, 2-ethoxy-1-[[2'-(1H-tetrazol-5-yl)biphenyl-4- yl]methyl]-1H-benzimidazole-7-carboxylic acid (CV-11974), and its prodrug, (+/-)-1-(cyclohexyloxycarbonyloxy)-ethyl 2-ethoxy-1-[[2'-(1H-tetrazol-5- yl)biphenyl-4-yl]methyl]-1H-benzimidazole-7-carboxylate (TCV-116).
1993 • 211 citations
Candesartan (CV-11974) dissociates slowly from the angiotensin AT1 receptor
1997 • 139 citations
Blood Pressure Effects of the Angiotensin II Receptor Blocker, Losartan
1995 • 99 citations
Ambulatory Blood Pressure Monitoring in the Evaluation of Antihypertensive Treatment: Additional Information from a Large Data Base
1995 • 96 citations
A randomised, double-blind comparison of the angiotensin II receptor antagonist, irbesartan, with the full dose range of enalapril for the treatment of mild-to-moderate hypertension
1998 • 89 citations
Effects of candesartan cilexetil in patients with severe systemic hypertension
1999 • 56 citations
Treatment of Ambulatory Hypertensives With Nebivolol or Hydrochlorothiazide Alone and in Combination
1994 • 42 citations
Twenty-four hour blood pressure profile of different doses of candesartan cilexetil in patients with mild to moderate hypertension.
1997 • 33 citations
Inhibition of angiotensin II pressor response and ex vivo angiotensin II radioligand binding by candesartan cilexetil and losartan in healthy human volunteers.
1997 • 27 citations
19 An accurate automated device for home blood pressure measurement at last! The Omron HEM-705CP
1994 • 18 citations
A024 Candesartan causes a long-lasting antagonism of the angiotensin II receptor mediated contractile effects in isolated vascular preparations: A comparison with losartan and its active metabolite (EXP 3174)
1998 • 10 citations
Clinical relevance of ambulatory versus clinic blood pressure when evaluating antihypertensive therapy.
1996 • 8 citations
Encapsulation of Commercially Available Losartan for Blinding Purposes Does Not Affect its Bioavailability
1998 • 2 citations