Back to search

A chemical-sensitive integrated-circuit: the operational transducer

Data up to Jan 2025

Published1985
Citations40
References35

Total Citations Per Year

Abstract

References (35)

Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements

1970 • 1,982 citations

A hydrogen-sensitive Pd-gate MOS transistor

1975 • 498 citations

Field effect transistor sensitive to penicillin

1980 • 496 citations

The extended gate chemically sensitive field effect transistor as multi-species microprobe

1983 • 340 citations

Potassium ion-sensitive field effect transistor

1975 • 234 citations

An Integrated Field-Effect Electrode for Biopotential Recording

1974 • 229 citations

ISFET's using inorganic gate thin films

1979 • 168 citations

An integrated NMOS operational amplifier with internal compensation

1976 • 152 citations

A miniature flow-through cell with a four-function chemfet integrated circuit for simultaneous measurements of potassium, hydrogen, calcium and sodium ions

1984 • 118 citations

Chemically Sensitive Field Effect Transistors

1980 • 118 citations

Temperature dependence of MOS transistor characteristics below saturation

1966 • 88 citations

Ion-sensitive field-effect transistors with inorganic gate oxide for pH sensing

1982 • 83 citations

A critical evaluation of the mechanism of potential response of antigen polymer membranes to the corresponding antiserum

1982 • 78 citations

The Suspended Mesh Ion Selective Field Effect Transistor

1982 • 73 citations

Detection of H2S with Pd-gate MOS field-effect transistors

1976 • 67 citations

Ion-selective field effect transistors with polymeric membranes

1978 • 67 citations

N-channel enhancement-mode MOSFET characteristics from 10 to 300 K

1981 • 65 citations

A field effect transistor as a solid-state reference electrode

1978 • 65 citations

Simultaneous on-line measurement of blood K+, Ca2+, Na+, and pH with a four-function ChemFET integrated-circuit sensor.

1984 • 52 citations

Simultaneous on-line measurement of blood K+, Ca2+, Na+, and pH with a four-function ChemFET integrated-circuit sensor.

1984 • 48 citations

Electrostatically protected ion sensitive field effect transistors

1984 • 36 citations

Chemical-sensitive field-effect transistors

1983 • 33 citations

Gate-controlled diodes for ionic concentration measurement

1979 • 33 citations

The Selectivity and Temperature Characteristics of Ion Sensitive Field Effect Transistors

1978 • 32 citations

Ion-selective field effect transistors with heterogeneous membranes

1979 • 30 citations

Preparation of Na+-selective electrodes by ion-implantation of lithium and silicon into single-crystal alumina wafer and its application to the production of ISFET

1982 • 30 citations

Online patient-monitoring system for the simultaneous analysis of blood K+, Ca2+, Na+ and pH using a quadruple-function ChemFET integrated-circuit sensor

1985 • 30 citations

A flow injection system for measurement of chemical response time of microelectrodes

1982 • 29 citations

An ionophoretic chemically-sensitive solid state transducer

1984 • 23 citations

Transient Phenomena in Ion Sensitive Field Effect Transistors

1980 • 23 citations

Monolithic integrated circuit implementations of the charge-flow transistor oscillator moisture sensor

1981 • 12 citations

Electronic-circuit-design principles for parameter control of i.s.f.e.t.s and related devices

1979 • 7 citations

Design considerations for an isfet multiplexer and amplifier

1984 • 6 citations

A chemically sensitive MOS element with an ultra thin dielectric film

1981 • 5 citations

A microelectronic pH sensor.

1976 • 4 citations

Cited By (0)

Loading...
A chemical-sensitive integrated-circuit: the operational transducer (1985) – Sensors and Actuators | Metascience Observatory Explorer