Void volume determination and experimental probes in reversed phase chromatography
Data up to Jan 2025
Total Citations Per Year
Abstract
References (20)
The Theory of Chromatography
1943 • 536 citations
Distribution phenomena of mobile-phase components and determination of dead volume in reversed-phase liquid chromatography
1980 • 436 citations
Performance and selected applications of a new range of chemically bonded packing materials in high-performance liquid chromatography
1975 • 260 citations
Theory of solvent disturbance peaks and experimentaldetermination of thermodynamic dead-volume in column liquid chromatography
1985 • 203 citations
Adsorption from liquid mixtures and liquid chromatography
1982 • 196 citations
On the Determination of the Hold-Up Time in Reversed Phase Liquid Chromatography
1980 • 175 citations
Distribution equilibria of solvent components in reversed-phase liquid chromatographic columns and relationship with the mobile phase volume
1981 • 171 citations
Role of organic modifier sorption on retention phenomena in reversed-phase liquid chromatography
1980 • 155 citations
Liquid chromatographic elution characteristics of some solutes used to measure column void volume on C18 bonded phases
1981 • 132 citations
Comparison of methods used for the determination of void volume in reversed-phase liquid chromatography
1982 • 132 citations
Adsorption isotherm at the liquid-solid interface and the interpretation of chromatographic data
1982 • 84 citations
Simple relationship concerning mobile and stationary phases in normal- and reversed-phase chromatography
1981 • 73 citations
Is there a “true” dead volume for HPLC columns?
1984 • 65 citations
Movement of components in reversed-phase chromatography
1983 • 57 citations
Elution characteristics of some solutes used to measure the column void time on reversed-phase stationary phases in micro-HPLC
1983 • 34 citations
Measurement of deuterium oxide elution data in reversed-phase liquid chromatography with a microwave induced plasma detection
1983 • 32 citations
Elution characteristic of sodium nitrite in reversed-phase HPLC with aqueous methanol as the mobile phase
1983 • 31 citations
Adsorption isotherms of organic modifiers and the determination of the dead volume in RPLC
1985 • 24 citations
Dead volume determination in reversed-phase liquid chromatography
1983 • 13 citations
Convenient estimation of the mobile phase volume for water-rich eluents in reversed-phase liquid chromatography
1984 • 11 citations