Back to search

Intracoronary air-filled albumin microspheres for myocardial blood flow measurement

Data up to Jan 2025

Published1993
Citations19
References28

Total Citations Per Year

Abstract

References (28)

Lack of myocardial perfusion immediately after successful thrombolysis. A predictor of poor recovery of left ventricular function in anterior myocardial infarction.

1992 • 1,068 citations

The behavior of sonicated albumin microbubbles within the microcirculation: a basis for their use during myocardial contrast echocardiography.

1989 • 276 citations

Functional significance of collateral blood flow in patients with recent acute myocardial infarction. A study using myocardial contrast echocardiography.

1992 • 235 citations

Contrast echocardiography in acute myocardial ischemia: I. In vivo determination of total left ventricular “area at risk”

1984 • 201 citations

Coronary blood flow in man

1976 • 193 citations

Assessment of regional myocardial blood flow with myocardial contrast two-dimensional echocardiography

1989 • 178 citations

Albunex: A Safe and Effective Commercially Produced Agent for Myocardial Contrast Echocardiography

1989 • 146 citations

Assessment of myocardial perfusion in humans by contrast echocardiography. I. Evaluation of regional coronary reserve by peak contrast intensity

1988 • 129 citations

Contrast echocardiography for evaluation of myocardial perfusion: Effects of coronary angioplasty

1986 • 108 citations

Intravenous contrast echocardiography with use of sonicated albumin in humans: Systolic disappearance of left ventricular contrast after transpulmonary transmission

1990 • 105 citations

Intraoperative cardioplegic contrast echocardiography for assessing myocardial perfusion during open heart surgery

1984 • 88 citations

Assessment of location and size of myocardial infarction with contrast-enhanced echocardiography

1983 • 76 citations

Myocardial contrast echocardiography for the assessment of coronary blood flow reserve: Validation in humans

1993 • 69 citations

Contrast echocardiographic mapping of collateralized myocardium in humans before and after coronary angioplasty

1990 • 63 citations

On-line intraoperative quantitation of regional myocardial perfusion during coronary artery bypass graft operations with myocardial contrast two-dimensional echocardiography

1992 • 60 citations

Coronary collaterals assessed with myocardial contrast echocardiography in healed myocardial infarction

1990 • 60 citations

Physical factors influencing quantitation of two-dimensional contrast echo amplitudes

1984 • 59 citations

Autoimmune determinants of rheumatic carditis: localization of epitopes in human cardiac myosin

1991 • 41 citations

Quantitative assessment of the immediate results of coronary angioplasty by myocardial contrast echocardiography

1989 • 39 citations

Myocardial Contrast Two-dimensional Echocardiography

1989 • 25 citations

Myocardial perfusion by contrast echocardiography. From off-line processing to radio frequency analysis.

1991 • 23 citations

Myocardial tissue recruitment in the dog as determined by double tracer dilution method.

1976 • 21 citations

Myocardial washout of sonicated iopamidol reflects coronary blood flow in the absence of autoregulation

1992 • 16 citations

Microvessel mean transit time and blood flow velocity of sulfhemoglobin-RBC

1980 • 15 citations

Flow quantitation by radio frequency analysis of contrast echocardiography

1993 • 15 citations

Intraoperative Contrast Echocardiography

1990 • 7 citations

Vascular volume changes in the dog forelimb

1964 • 6 citations

Deleted Work

1955 • 0 citations

Cited By (0)

Loading...