Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame
Data up to Jan 2025
Total Citations Per Year
Abstract
References (26)
The use of active breathing control (ABC) to reduce margin for breathing motion
1999 • 903 citations
Stereotactic High Dose Fraction Radiation Therapy of Extracranial Tumors Using An Accelerator: Clinical experience of the first thirty-one patients
1995 • 842 citations
Stereotactic Radiotherapy of Malignancies in the Abdomen: Methodological aspects
1994 • 540 citations
Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing
1996 • 372 citations
Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients
1998 • 306 citations
Accuracy of radiation field alignment in clinical practice
1985 • 274 citations
What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?
1998 • 272 citations
Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging
1998 • 238 citations
Radiosurgery for Tumors in the Body: Clinical Experience Using a New Method
1998 • 227 citations
Prostate target volume variations during a course of radiotherapy
1998 • 220 citations
Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases
2000 • 203 citations
Diaphragmatic and cardiac motion during suspended breathing: preliminary experience and implications for breath-hold MR imaging.
1998 • 192 citations
Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer
1992 • 175 citations
Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer
1996 • 164 citations
Bladder movement during radiation therapy for bladder cancer: Implications for treatment planning
1997 • 111 citations
A critical evaluation of the planning target volume for 3-D conformal radiotherapy of prostate cancer
1998 • 106 citations
Kidney mobility during respiration
1994 • 100 citations
Extracranial Stereotactic Radiosurgery of Localized Targets
1998 • 99 citations
Lung cancer: intermittent irradiation synchronized with respiratory motion--results of a pilot study.
1998 • 98 citations
Potential benefits of eliminating planning target volume expansions for patient breathing in the treatment of liver tumors
1997 • 97 citations
CT simulation in stereotactic brain radiotherapy — analysis of isocenter reproducibility with mask fixation
1997 • 83 citations
Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy
1994 • 77 citations
Set-up error in supine-positioned patients immobilized with two different modalities during conformal radiotherapy of prostate cancer
1998 • 64 citations
Impact of cradle immobilization of setup reproducibility during external beam radiation therapy for lung cancer
1997 • 41 citations
Radiotherapy of pelvic malignancies: impact of two types of rigid immobilisation devices on localisation errors
1999 • 28 citations
Extracranial stereotactic conformal radiation treatment of tumors in the liver and the lung
1998 • 5 citations
Cited By (0)
No citing papers found in database