Back to search

Characteristics of contamination electrons in high energy photon beams

Data up to Jan 2025

Published1993
Citations34
References34

Total Citations Per Year

Abstract

References (34)

Radiation Quantities and Units

1972 • 291 citations

The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom

1991 • 116 citations

Calibration and use of Plane-Parallel Ionization Chambers for the Determination of Absorbed Dose in Electron Beams

1981 • 88 citations

Electrons as the cause of the observed dmax shift with field size in high energy photon beams

1979 • 86 citations

Determination of effective bremsstrahlung spectra and electron contamination for photon dose calculations

1989 • 85 citations

Investigation of buildup dose from electron contamination of clinical photon beams

1983 • 84 citations

Sources of electron contamination for the Clinac‐35 25‐MV photon beam

1983 • 84 citations

The Partition of Kerma to Account For Bremsstrahlung

1979 • 68 citations

An investigation into the presence of secondary electrons in megavoltage photon beams (radiotherapy application)

1983 • 65 citations

A formalism for calculation of absorbed dose to a medium from photon and electron beams

1981 • 58 citations

Absorbed dose from secondary electrons in high energy photon beams

1979 • 58 citations

Electron contamination from photon beam collimators

1986 • 46 citations

Contamination of a 15-MV photon beam by electrons and scattered photons.

1982 • 44 citations

Dosimetry and Quality Specification of High Energy Photon Beams

1986 • 42 citations

Characteristics of an 18 MV photon beam from a Therac 20 Medical Linear Accelerator

1981 • 41 citations

Improving the buildup and depth‐dose characteristics of high energy photon beams by using electron filters

1979 • 40 citations

Magnetic analysis of the radiation components of a 10 MV photon beam

1982 • 38 citations

Contamination of high-energy photon beams by scattered photons.

1981 • 38 citations

The effect of collimator backscatter radiation on photon output of linear accelerators

1987 • 36 citations

Air-generated electron contamination of 4 and 10 MV photon beams: a comparison of theory and experiment

1985 • 29 citations

Electron contamination in 6 0 Co gamma-ray beams

1983 • 27 citations

Relation Between Kerma and Absorbed Dose in Photon Beams

1983 • 26 citations

Buildup region and skin‐dose measurements for the Therac 6 Linear Accelerator for radiation therapy

1981 • 22 citations

Bases physiques de la radiothérapie et de la radiobiologie

1963 • 22 citations

Measurement of beam current and evaluation of scatter production in an 18-MeV accelerator

1987 • 22 citations

Ion Chambers for Neutron Dosimetry

1981 • 19 citations

On the use of a quality index to specify high energy photon beams

1986 • 13 citations

Contaminant electrons in the build-up region of a 4 MV photon beam

1983 • 13 citations

Surface dose from 6 MV photon interactions in air

1983 • 12 citations

Calculational methods for estimating skin dose from electrons in Co‐60 gamma‐ray beams

1983 • 9 citations

Characteristics of the high‐energy photon beam of a 25‐MeV accelerator

1988 • 6 citations

Properties of the 18‐MV photon beam from a dual energy linear accelerator

1987 • 4 citations

Modelisation des distributions de dose sur l'axe pour les faisceaux de photons de haute energie utilises en radiotherapie

1987 • 3 citations

Determination De La Fonction De Diffusion De Rayons X De 25 Mv Dans Un Milieu Equivalent-Tissu

1975 • 2 citations

Cited By (0)

Loading...
Characteristics of contamination electrons in high energy photon beams (1993) – Radiotherapy and Oncology | Metascience Observatory Explorer