Back to search

Influence of Pathologic Blood Cell Microrheology on Myocardial Microcirculation in Cardiac Surgery Using Cardiopulmonary Bypass

Data up to Jan 2025

Published1990
Citations6
References21

Total Citations Per Year

Abstract

References (21)

Leukocyte capillary plugging in myocardial ischemia and reperfusion in the dog.

1983 • 845 citations

LASER DOPPLER MEASUREMENT OF CUTANEOUS BLOOD FLOW

1977 • 535 citations

An ultrasonic pulsed Doppler system for measuring blood flow in small vessels.

1974 • 356 citations

Interarterial Coronary Anastomoses in the Human Heart, with Particular Reference to Anemia and Relative Cardiac Anoxia

1951 • 249 citations

White blood cell deformability and plugging of skeletal muscle capillaries in hemorrhagic shock

1980 • 195 citations

The Laser Doppler flowmeter for microvascular monitoring: a preliminary report

1982 • 95 citations

Measurement of microvascular blood flow in cancellous bone using laser Doppler flowmetry and 133Xe-clearance

1983 • 85 citations

On the significance of coronary collaterals

1969 • 45 citations

Rhythmical oscillations in rat testicular microcirculation as recorded by laser Doppler flowmetry

1983 • 42 citations

Decreased Red Cell Deformability Following Open-Heart Surgery

1983 • 41 citations

Changes in Red Cell Deformability Associated with Anaesthesia and Cardiopulmonary Bypass in Open-Heart Surgery

1985 • 29 citations

Evaluation of Red Cell Damage During Cardiopulmonary Bypass

1985 • 25 citations

Cutaneous microcirculation and blood rheology following cardiopulmonary bypass: Laser Doppler Flowmetric and Blood Cell Rheologic Studies

1988 • 25 citations

Association between bleeding and reduced red cell deformability following cardiopulmonary bypass

1988 • 19 citations

A preliminary study of rheology of granulocytes

1970 • 17 citations

Association between pulmonary dysfunction and reduced red cell deformability following cardiopulmonary bypass

1988 • 14 citations

Association between arrhythmias and reduced red cell deformability following cardiopulmonary bypass

1988 • 14 citations

Measurement of point velocity in the canine coronary artery by laser Doppler velocimeter with optical fiber

1981 • 11 citations

Biological Analysis of Blood Trauma: The Response of the Unspecific Defense System to Foreign Technical Apparatus

1979 • 8 citations

Comparison of Terumo Hollow Fiber Membrane and Harvey 1500 Bubble Oxygenators Using Red Cell Microrheology Analysis during Cardiopulmonary Bypass

1987 • 6 citations

Deleted Work

1955 • 0 citations

Cited By (0)

Loading...