Back to search

Modification in the surface composition of sparked electrodes and its relation to relative sensitivity factors in spark source mass spectrometry

Data up to Jan 2025

Published1985
Citations8
References27

Total Citations Per Year

Abstract

References (27)

Geochemical application of spark source mass spectrography—III. Element sensitivity, precision and accuracy

1977 • 295 citations

Quantitative Mass Spectrometry of Solids.

1963 • 59 citations

The Effect of Electrode Temperature on Vacuum Electrical Breakdown between Plane-Parallel Copper Electrodes

1968 • 54 citations

Emission and electrode erosion properties of a positionally stable spark discharge train

1981 • 31 citations

Zustandsänderungen der Probe im Abfunkbereich bei der optischen Emissionsspektralanalyse von Stahl

1967 • 22 citations

The analysis of tiiin films by SSMS - A more detailed discharge model and recent experiments

1980 • 21 citations

Spark gap effects on sensitivity in spark source mass spectrometry

1973 • 19 citations

Optical and x-ray studies of metal surfaces eroded by high-voltage oscillatory spark discharges

1969 • 17 citations

Statistical Mapping of Alloy Samples by Spark Excited Optical Emission Spectroscopy

1983 • 15 citations

Electrical breakdown between stainless-steel electrodes in vacuum

1982 • 13 citations

Relative sensitivity coefficients for the analysis of steel by spark-source mass-spectrometry

1976 • 13 citations

Abbauvorgänge und Interelementeffekte bei der optischen Emissionsspektralanalyse von Stahl—II

1968 • 13 citations

Influence of matrix on relative sensitivity factors in spark-source mass spectrometric analysis

1980 • 12 citations

Anorganische massenspektrometrische Analyse

1964 • 12 citations

Study of high-voltage breakdown and material consumption in spark-source mass spectrometry and their significance in analytical applications

1984 • 12 citations

Influence of sparking conditions and of electrode temperature on the relative elemental sensitivity in spark-source mass spectrometry

1979 • 8 citations

Mass-spectrometric multielement analysis of copper and copper-base alloys, with electrical detection

1977 • 8 citations

Determination of homogeneity of standard materials by ion microscopy

1981 • 7 citations

On relative sensitivity coefficients of spark source mass spectrographic analysis of steels

1973 • 7 citations

Sensitivity calibration for the spark-source mass-spectrometric analysis of aluminium and its alloys

1978 • 6 citations

Relative Sensitivity Coefficients of Elements in Spark Source Mass Spectrometry

1964 • 5 citations

Effects of several experimental parameters on the relative sensitivity factors in spark-source mass spectrometric analysis of steel

1978 • 5 citations

Discrimination effects in the composition of the ion beam derived from AAS analysis of deposits and optical emission spectra of emitted spark light during analysis by SSMS

1983 • 5 citations

Spark source mass spectrometry for trace analysis of diverse biological matrices

1983 • 5 citations

Scanning electron microscope surface observations of electrodes sparked in a spark source spectrometer

1983 • 4 citations

Effects of source parameters on ion intensities in spark source mass spectrograph

1969 • 3 citations

A comparison between secondary-ion mass-spectrometry and spark-source mass-spectrometry for the quantitative analysis of steel wire

1982 • 2 citations

Cited By (0)

Loading...