Back to search

Acetabular micromotion as a measure of initial implant stability in primary hip arthroplasty

Data up to Jan 2025

Published1992
Citations101
References54

Total Citations Per Year

Abstract

References (54)

Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced Implants

1986 • 1,116 citations

The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone

1980 • 824 citations

Total hip replacement in patients younger than thirty years old. A five-year follow-up study.

1981 • 662 citations

Ten-year follow-up study of total hip replacement.

1982 • 637 citations

A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties.

1982 • 600 citations

Revision total hip arthroplasty.

1985 • 560 citations

A biomechanical investigation of the human hip

1978 • 447 citations

Telemetric force measurements across the hip after total arthroplasty.

1988 • 413 citations

The effect of movement on the bonding of porous metal to bone

1973 • 385 citations

Localized osteolysis in stable, non-septic total hip replacement.

1986 • 333 citations

Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty.

1990 • 277 citations

Cement Disease

1987 • 238 citations

15???21-year Results of the Charnley Low-friction Arthroplasty

1986 • 204 citations

Macroscopic and Microscopic Evidence of Prosthetic Fixation with Porous-Coated Materials

1988 • 192 citations

Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implants

1977 • 176 citations

Total hip arthroplasties in patients younger than 45 years. A nine- to ten-year follow-up study.

1990 • 174 citations

Cemented total hip replacement in patients who are less than fifty years old.

1984 • 167 citations

Biomechanical and Histologic Investigation of Cemented Total Hip Arthroplasties

1989 • 157 citations

Biomechanical and histologic investigation of cemented total hip arthroplasties. A study of autopsy-retrieved femurs after in vivo cycling.

1989 • 152 citations

The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study.

1983 • 143 citations

Femoral lysis after cemented hip arthroplasty

1988 • 140 citations

Structures at risk from medially placed acetabular screws.

1990 • 134 citations

Stress distributions in the acetabular region—I. Before and after total joint replacement

1982 • 129 citations

A Fifteen-Year Follow-up Study of One Hundred Charnley Low-Friction Arthroplasties

1988 • 121 citations

Radiographic and morphologic studies of load-bearing porous-surfaced structured implants.

1981 • 119 citations

Survivorship analysis of total hip replacements. Results in a series of active patients who were less than fifty-five years old.

1986 • 117 citations

Bony Ingrowth Fixation of the Acetabular Component in Canine Hip Joint Arthroplasty

1983 • 112 citations

Mechanical function of subchondral bone as experimentally determined on the acetabulum of the human pelvis

1976 • 104 citations

Total Hip Arthroplasties in Patients Younger Than 45 Years

1990 • 102 citations

Radiographic and Morphologic Studies of Load-Bearing Porous-Surfaced Structured Implants

1981 • 94 citations

The Madreporic Cementless Total Hip Arthroplasty

1983 • 93 citations

Cementless Total Hip Arthroplasty

1983 • 88 citations

Survivorship analysis of 1,041 charnley total hip arthroplasties

1990 • 87 citations

Cementless Press-Fit Cup Principles, Experimental Data, and Three-Year Follow-Up Study

1989 • 81 citations

In vitro initial fixation of porous-coated acetabular total hip components

1989 • 76 citations

Mechanical stability of porous-coated acetabular components in total hip arthroplasty

1991 • 74 citations

Failures of total hip arthroplasty and probable incidence of revision surgery in the future

1983 • 73 citations

The hip : proceedings of the 8th Open Scientific Meeting of The Hip Society, 1980

1980 • 67 citations

Mittelmeier ceramic total hip arthroplasty

1988 • 66 citations

Biologic Fixation and Bone Modeling with an Unconstrained Canine Total Knee Prosthesis

1982 • 65 citations

Factors affecting the mechanical stability of the cemented acetabular component in total hip replacement

1977 • 58 citations

Revision total hip arthroplasty in patients younger than 55 years old

1988 • 53 citations

Bony Ingrowth Fixation of Newly Designed Acetabular Components in a Canine Model

1983 • 44 citations

Periacetabular Stress Distributions After Joint Replacement with Subchondral Bone Retention

1983 • 42 citations

Five to Fourteen Year Interim Results of Uncemented Total Hip Arthroplasty

1978 • 41 citations

The Art of Total Hip Arthroplasty

1987 • 37 citations

Radiographic Performance of Two Different Total Hip Cemented Arthroplasties

1988 • 29 citations

Evidence of bone ingrowth into a porous-coated prosthesis. A case report.

1984 • 28 citations

Theory and practice of cementless revision total hip arthroplasty.

1987 • 17 citations

Role of surgical preparation in acetabular cup fixation.

1980 • 14 citations

Pelvic stresses in vitro—II. A study of the efficacy of metal-backed acetabular prostheses

1986 • 12 citations

European experience with cementless total hip replacements.

1983 • 6 citations

The effect of endoprosthetic mismatch and metal- or non-metal-backed acetabular components on in vitro pelvic stresses.

1985 • 1 citations

Deleted Work

1955 • 0 citations

Cited By (0)

Loading...