Back to search

Potential and limitations of differently designed programmed‐temperature injector liners for large volume sample introduction in capillary GC

Data up to Jan 2025

Published1993
Citations45
References29

Total Citations Per Year

Abstract

References (29)

Sampling method in capillary column gas—liquid chromatography allowing injections of up to 250 μl

1979 • 121 citations

Capillary gas chromatographic injection system for large sample volumes

1979 • 110 citations

Headspace gas analysis: the role and the design of concentration traps specifically suitable for capillary gas chromatography

1985 • 86 citations

Headspace gas analysis

1986 • 78 citations

Comparative assessment of the artefact background on thermal desorption of tenax GC and tenax TA

1986 • 77 citations

Solvent elimination rate in temperature-programmed injections of large sample volumes in capillary gas chromatography

1992 • 60 citations

Use of an open-tubular trapping column as phase-switching interface in on-line coupled reversed-phase liquid chromatography—capillary gas chromatography

1993 • 50 citations

Programmed‐temperature injector for large‐volume sample introduction in capillary gas chromatography and for liquid chromatography‐gas chromatography interfacing

1992 • 46 citations

Tenax-GC cartridge for interfacing capillary column gas chromatography with adsorption/thermal desorption for determination of trace organics

1982 • 40 citations

Sampling of volatile components using a PTV in the solvent split mode

1987 • 39 citations

Headspace analysis: A novel method for the production of capillary traps with ultra‐thick stationary phase layers

1990 • 38 citations

Sample as its own stationary phase in gas chromatography

1971 • 38 citations

A simple method for concentrating dilute high-boiling samples for capillary gas chromatography

1975 • 37 citations

Preparative capillary gas chromatography

1987 • 36 citations

New methodologies in trace analysis of volatile organic compounds

1989 • 30 citations

Improved thick film open tubular traps for the enrichment of volatile organic compounds from air and water

1990 • 29 citations

Trace analysis of complex organic mixtures using capillary gas‐liquid chromatography and the dynamic solvent effect

1987 • 24 citations

Optimization of the cold split‐splitless injector in the solvent‐split mode

1988 • 21 citations

Deactivation of fused-silica capillary columns with polymethylhydrosiloxanes

1986 • 20 citations

Large sample injection method (≥ 100 μL) for capillary GC using a commercial thermodesorption unit as injection device

1984 • 19 citations

Experiments with the PTV in the solvent split mode for concentration of volatiles

1989 • 19 citations

Evaluation of a PTV injector for quantitative analysis of volatile compounds at low concentrations

1989 • 16 citations

Deactivation with polymethylhydrosiloxane

1989 • 16 citations

Preparation of thermally stable phenylpolysiloxane fused silica capillary columns. Optimization and evaluation of the deactivation by capillary GC and solid state 29Si NMR

1990 • 8 citations

Solvent removal/thermal desorption (SRTD) for extract concentration and capillary column injection

1987 • 5 citations

Salute focusing by means of the solvent effect: formation of the film

1983 • 4 citations

Comparison between the conditions for solute focussing by the static and dynamic solvent effects under ideal conditions

1989 • 3 citations

High precision trace analysis in capillary gas‐liquid chromatography using an inlet based on the static solvent effect

1987 • 3 citations

High-precision sampling of sub-nanograms, low-parts-per-billion solutes from liquids using the dynamic solvent effect

1990 • 2 citations

Cited By (0)

Loading...