Electrochemical detectors for flowing liquid systems
Data up to Jan 2025
Total Citations Per Year
Abstract
References (87)
Theory of Stationary Electrode Polarography. Single Scan and Cyclic Methods Applied to Reversible, Irreversible, and Kinetic Systems.
1964 • 4,891 citations
Novel ion exchange chromatographic method using conductimetric detection
1975 • 1,368 citations
AUTOMATION IN ANALYTICAL CHEMISTRY
1967 • 980 citations
Liquid chromatographic analysis of catecholamines routine assay for regional brain mapping
1976 • 734 citations
A sensitive method for the determination of plasma catecholamines using liquid chromatography with electrochemical detection
1978 • 445 citations
New high performance liquid chromatographic analysis of brain catecholamines
1974 • 236 citations
Mercury-based electrochemical detector for liquid chromatography for the detection of glutathione and other sulfur-containing compounds
1977 • 167 citations
Determination of serotonin and dopamine in mouse brain tissue by high performance liquid chromatography with electrochemical detection
1977 • 165 citations
Estimation of catecholamines in urine by high performance liquid chromatography with electrochemical detection
1975 • 149 citations
Optimized isocratic conditions for analysis of catecholamines by high-performance reversed-phase paired-ion chromatography with amperometric detection
1978 • 146 citations
Flow coulometric detector for liquid chromatography
1973 • 132 citations
Determination of ascorbic acid in foodstuffs, pharmaceuticals, and body fluids by liquid chromatography with electrochemical detection
1976 • 121 citations
Design and characterization of a coulometric detector with a glassy carbon electrode for high-performance liquid chromatography
1976 • 121 citations
Dual electrochemical detector for liquid chromatography
1976 • 118 citations
Determination of urinary normetanephrine, metanephrine, and 3-methoxytyramine by liquid chromatography, with amperometric detection.
1977 • 112 citations
Amperometric and differential pulse voltammetric detection in high performance liquid chromatography
1976 • 100 citations
Monitoring of transmitter metabolites by voltammetry in cerebrospinal fluid following neural pathway stimulation
1976 • 98 citations
Evaluation of the basal plane of pyrolytic graphite as an electrochemical detector for liquid chromatography
1978 • 97 citations
Liquid chromatography detector based on single and twin electrode thin-layer electrochemistry: application to the determination of catecholamines in blood plasma
1978 • 95 citations
Electrochemical Detection of Selected Organic Components in the Eluate from High-Performance Liquid-Chromatography
1974 • 92 citations
Identification of salsolinol as a major dopamine metabolite in the banana
1976 • 84 citations
Determination of Acetaminophen in Pharmaceutical Preparations and Body Fluids by High-Performance Liquid Chromatography with Electrochemical Detection
1975 • 79 citations
Electrochemical flow-through detector for the determination of cystine and related compounds
1978 • 75 citations
Determination of nitrate and nitrite by forced-flow liquid chromatography with electrochemical detection
1974 • 74 citations
Forced-flow liquid chromatography with a coulometric detector
1973 • 70 citations
Reticulated vitreous carbon flow-through electrodes
1979 • 69 citations
Anodic coulometric detection with a glassy carbon electrode in combination with reversed-phase high-performance liquid chromatography
1976 • 66 citations
Voltammetric studies with silicone rubber-based graphite electrodes
1968 • 64 citations
Determination of tetrahydroisoquinoline alkaloids in biological materials with high performance liquid chromatography
1977 • 63 citations
Applications of Modern Electroanalytical Techniques to Pharmaceutical Chemistry
1969 • 62 citations
Amperometric enzymic determination of total cholesterol in human serum with tubular carbon electrodes
1979 • 60 citations
Determination of homovanillic acid in urine by liquid chromatography with electrochemical detection
1976 • 59 citations
Small-volume solid-elcetrode flow-through electrochemical cells
1973 • 58 citations
Liquid chromatographic method for monitoring therapeutic concentrations of L-dopa and dopamine in serum.
1976 • 58 citations
Submicromolar concentration measurements with tubular electrodes
1971 • 57 citations
A hydrodynamic voltammetric study of the ferricyanide/ferrocyanide system with convective electrodes of platinum, gold, glassy carbon, carbon film, and boron carbide
1977 • 55 citations
In vivo voltammetry: Monitoring of dopamine metabolites in CSF following release by electrical stimulation
1978 • 52 citations
Continuous Quantitative Electrolysis.
1964 • 52 citations
Polarographic Study with a Microelectrode Past which an Electrolyte is Flowing1
1947 • 52 citations
Voltammetry in brain tissue: The fate of injected 6-hydroxydopamine
1974 • 49 citations
Automatic fraction collectors and a conductivity recorder
1951 • 44 citations
Continuous Deaeration and Polarograpic Analysis of Column Effluents
1958 • 43 citations
Determination of O-methylated metabolites of cathecholamines using high- performance liquid chromatography and electrochemical detection
1978 • 43 citations
Liquid chromatographic analysis of nanogram quantities of ascorbate in brain tissue
1974 • 43 citations
New liquid chromatography approach to plant phenolics. Application to the determination of chlorogenic acid in sunflower meal
1976 • 42 citations
Determination of antimony using forced-flow liquid chromatography with a coulometric detector
1974 • 40 citations
The use of precipitate based silicone rubber ion-selective electrodes and silicone rubber based graphite voltammetric electrodes in continuous analysis. A review
1974 • 40 citations
Determination of purine bases by means of chromato-voltammetry
1974 • 35 citations
Colorimetric, Enzymatic, and Liquid-Chromatographic Methods for Serum Uric Acid Compared
1975 • 35 citations
Polarographic Cell for the Continuous Analysis of Flowing Solutions.
1964 • 34 citations
Application of a coulometric detector to rapid ion-exchange chromatography
1975 • 28 citations
New electrochemical detector for high-performance liquid chromatography
1978 • 27 citations
Electrochemical Fractionation: Potentiostatic Chromatography and Elution Voltammetry.
1964 • 27 citations
Design and characterization of electrochemical detector for high-performance liquid chromatography and application to the determination of biogenic amines.
1978 • 26 citations
Liquid chromatographic determination of picomole quantities of aromatic amine carcinogens
1977 • 26 citations
The voltammetric application of silicone rubber based graphite electrodes with special regard to flowing systems
1975 • 26 citations
Anodic stripping voltammetry in a flow-through cell with a fixed mercury film glassy carbon disc electrode. Part I
1977 • 25 citations
Polarographic Cell for Continuous Monitoring of Ion Exchange Effluents
1957 • 25 citations
A Method for Obtaining Continuous Records of Dissolved Oxygen in Lake Waters
1940 • 24 citations
A System for Automated Polarographic Analysis
1973 • 24 citations
A new approach to the phenolic components in beer. Application to the determination of sinapic, ferulic, and p-coumaric acids
1977 • 24 citations
Turbulent tubular electrode
1974 • 23 citations
Polarographic Analysis Using Flowing Samples
1953 • 23 citations
Continuous Polarographic Analysis of Ion Exchange Effluents
1958 • 22 citations
Use of a Four-Cell Conductivity Bridge as a Continuous Detector for Ion Exchange Chromatography.
1962 • 21 citations
A simple high frequency transistor recorder for chromatography
1965 • 21 citations
A Polarographic Cell for the Continuous Monitoring of Column Effluents and Its Application to the Determination of Nitropyridine Derivatives
1975 • 20 citations
High-pressure liquid chromatographic analysis of isomeric aminophenols with electrochemical detection
1977 • 20 citations
Sensitive low volume conductivity detector for liquid chromatography
1968 • 19 citations
Monitoring insect infestation in cereal products—determination of traces of uric acid by high-pressure liquid chromatography
1977 • 19 citations
BeitrÄge zur Analyse einiger insecticider ThiophosphorsÄureester
1959 • 19 citations
Determination of Methyldopa in Pharmaceutical Dosage Forms and Biological Fluids Based on Oxidation at the Tubular Carbon Electrode
1974 • 17 citations
Continuous Polarographic Determination of α-Amino Acids
1961 • 17 citations
Flow-through electrochemical cell with open liquid junction
1978 • 17 citations
Current-time characteristics of the rapidly dropping mercury electrode
1960 • 16 citations
Polarographic determination of some pharmaceutical products: bromphenindione, trihydroxyethylrutoside, glibenclamide, coenzyme a, doxycycline.
1972 • 15 citations
Determination of β-cetotetrine in plasma and urine using high-performance liquid chromatography with electrochemical detection
1976 • 15 citations
Automatic recording of ion concentration in flowing solution
1954 • 15 citations
Determination of homogentisic acid in serum and urine by liquid chromatography with amperometric detection
1976 • 15 citations
Novel electrochemical reactor
1976 • 13 citations
Use of the Dropping-Mercury Electrode for the Continuous Measurement of Dissolved Oxygen in Flowing Water
1948 • 13 citations
A simple liquid chromatography procedure for p-aminohippuric acid in blood serum and urine
1975 • 12 citations
Computer-Assisted high-pressure liquid chromatography of radio-labelled phenylthiohydantoin amino acids
1978 • 12 citations
Dissolved Oxygen Recordings with Dropping Mercury Electrode
1942 • 12 citations
High-Pressure Liquid Chromatographic Determination of 8-Hydroxycarteolol in Plasma and Urine Using Electrochemical Detection
1978 • 11 citations
Noninvasive Polarographic Measurement of Drug Dissolution
1978 • 7 citations
Ein schwefelselektiver detektor für die flüssigkeits-chromatographie auf konduktometrischer basis
1977 • 3 citations