Lead vegetations in patients with local and systemic cardiac device infections: prevalence, risk factors, and therapeutic effects

Data up to Jan 2025

Published2012
Citations39
References49

Total Citations Per Year

Abstract

References (49)

Proposed Modifications to the Duke Criteria for the Diagnosis of Infective Endocarditis

2000 • 3,775 citations

Guidelines on the prevention, diagnosis, and treatment of infective endocarditis (new version 2009): The Task Force on the Prevention, Diagnosis, and Treatment of Infective Endocarditis of the European Society of Cardiology (ESC)

2009 • 1,930 citations

Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient Management

2009 • 994 citations

Update on Cardiovascular Implantable Electronic Device Infections and Their Management

2010 • 971 citations

Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections

2007 • 707 citations

Risk Factors Related to Infections of Implanted Pacemakers and Cardioverter-Defibrillators

2007 • 674 citations

Systemic Infection Related to Endocarditis on Pacemaker Leads

1997 • 596 citations

Lead Extraction in the Contemporary Setting: The LExICon Study

2010 • 522 citations

Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac Devices

2000 • 502 citations

Continued Rise in Rates of Cardiovascular Implantable Electronic Device Infections in the United States: Temporal Trends and Causative Insights

2009 • 381 citations

Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients

2011 • 348 citations

Pacemaker infective endocarditis

1998 • 314 citations

Staphylococcus aureus Bacteremia in Patients With Permanent Pacemakers or Implantable Cardioverter-Defibrillators

2001 • 284 citations

Infective Endocarditis Complicating Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infection

2008 • 275 citations

Cardiac implantable electronic device infections: Presentation, management, and patient outcomes

2010 • 263 citations

Pacemaker Endocarditis Report of 44 Cases and Review of the Literature

1994 • 255 citations

Surgical Treatment of Pacemaker and Defibrillator Lead Endocarditis

2003 • 246 citations

Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads

2008 • 240 citations

Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT‐CRT): Design and Clinical Protocol

2005 • 221 citations

Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper

2011 • 197 citations

Local symptoms at the site of pacemaker implantation indicate latent systemic infection

2004 • 192 citations

Device‐Related Infection Among Patients With Pacemakers and Implantable Defibrillators: Incidence, Risk Factors, and Consequences

2010 • 191 citations

Percutaneous Pacemaker and Implantable Cardioverter-Defibrillator Lead Extraction in 100 Patients With Intracardiac Vegetations Defined by Transesophageal Echocardiogram

2010 • 139 citations

Microbiology of cardiac implantable electronic device infections

2012 • 135 citations

The Role of Swab and Tissue Culture in the Diagnosis of Implantable Cardiac Device Infection

2005 • 132 citations

Long-term infection rates associated with the pectoral versus abdominal approach to cardioverter- defibrillator implants

2001 • 120 citations

Pacemaker Endocarditis: Clinical Features and Management of 60 Consecutive Cases

2007 • 116 citations

Endocarditis in Patients with a Permanent Pacemaker: A 1-Year Epidemiological Survey on Infective Endocarditis due to Valvular and/or Pacemaker Infection

2004 • 115 citations

End-Stage Renal Disease Predicts Complications in Pacemaker and ICD Implants

2011 • 112 citations

Pacemaker Endocarditis During 18 Years in Göteborg

2004 • 110 citations

Endocardial pacemaker or defibrillator leads with infected vegetations: a single-center experience and consequences of transvenous extraction

2003 • 105 citations

Pacemaker Infections: A 10-Year Experience

2007 • 93 citations

Mobile Thrombus on Device Leads in Patients Undergoing Ablation

2011 • 88 citations

Recurrent Implantable Cardioverter-Defibrillator Replacement Is Associated with an Increasing Risk of Pocket-Related Complications

2010 • 83 citations

Incidence and Significance of Pacemaker and Implantable Cardioverter‐Defibrillator Lead Masses Discovered during Transesophageal Echocardiography

2011 • 75 citations

Incidence and prognosis of pacemaker lead-associated masses: a study of 1,569 transesophageal echocardiograms.

2006 • 63 citations

Intracardiac Echocardiography in Patients with Pacing and Defibrillating Leads: A Feasibility Study

2008 • 62 citations

Pacemaker and Defibrillator Lead Extraction: Predictors of Mortality during Follow-Up

2009 • 62 citations

Permanent transvenous pacemaker infections: An analysis of 59 cases

2007 • 42 citations

Intracardiac echocardiography in the detection of pacemaker lead endocarditis

2002 • 42 citations

MADIT-II: clinical implications.

2002 • 42 citations

Bacteriology of infected extracted pacemaker and ICD leads

2009 • 38 citations

Detailed bacteriologic tests to identify the origin of transvenous pacing system infections indicate a high prevalence of multiple organisms

2005 • 36 citations

High Mid-Term Mortality Following Successful Lead Extraction for Infection

2010 • 30 citations

Accuracy of Swabs, Tissue Specimens, and Lead Samples in Diagnosis of Cardiac Rhythm Management Device Infections

2009 • 25 citations

European Heart Rhythm Association. Pathways for training and accreditation for transvenous lead extraction: A European Heart Rhythm Association position paper

2012 • 16 citations

Successful Laser‐Assisted Removal of an Infected ICD Lead with a Large Vegetation

2006 • 13 citations

Role of the Echocardiography Laboratory in Diagnosis and Management of Pacemaker and Implantable Cardiac Defibrillator Infection

2007 • 13 citations

Prospective evaluation of new criteria for the diagnosis of pacemaker lead infection: Limitation of the clinical DUKE criteria for the diagnosis of endocarditis

2005 • 3 citations