Back to search

Liquid chromatography amperometric detection of catechol, resorcinol, and hydroquinone with a copper‐based chemically modified electrode

Data up to Jan 2025

Published1992
Citations16
References17

Total Citations Per Year

Abstract

References (17)

Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts

1985 • 414 citations

Constant potential amperometric detection of carbohydrates at a copper-based chemically modified electrode

1989 • 172 citations

Constant potential amperometric detection at a copper-based electrode: electrode formation and operation

1990 • 163 citations

The behaviour of an electrochemical detector used in liquid chromatography and continuous flow voltammetry

1978 • 131 citations

Electrocatalysis and detection of amino sugars, alditols, and acidic sugars at a copper-containing chemically modified electrode

1989 • 110 citations

Amperometric and differential pulse voltammetric detection in high performance liquid chromatography

1976 • 100 citations

Amperometric detection of amino acids in high-performance liquid chromatography with a copper electrode

1983 • 76 citations

Amperometric detection of amino acids with a passivated copper electrode

1982 • 71 citations

Electrochemical Detection in High-Performance Liquid Chromatography

1984 • 58 citations

Indirect Potentiometric Determination of Metal Ions by Flow-Injection Analysis with a Copper Electrode

1984 • 55 citations

Application of a copper electrode as a detector for high-peformance liquid chromatography

1978 • 37 citations

High-performance liquid chromatography of organic acids with potentiometric detection using a metallic copper electrode

1984 • 37 citations

Operation parameters of voltammetric high-performance liquid chromatographic detectors with copper electrodes and application to a determination of some fodder biofactors

1986 • 34 citations

Potentiometric detection in ion chromatography using a metallic copper indicator electrode

1985 • 33 citations

Determination of oxalic acid in biological matrices by liquid chromatography with amperometric detection

1984 • 29 citations

Flow rate and column-parameter dependence of amperometric detector response in liquid chromatography with electrochemical detection

1987 • 24 citations

Approaches to the liquid chromatographic determination of carboxylic acids using potentiometric detection with a metallic copper electrode

1987 • 13 citations

Cited By (0)

Loading...