DNA sequencing in a monolithic microchannel device
Data up to Jan 2025
Total Citations Per Year
Abstract
References (24)
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
1992 • 1,205 citations
Planar chips technology for miniaturization and integration of separation techniques into monitoring systems
1992 • 1,008 citations
Functional Integration of PCR Amplification and Capillary Electrophoresis in a Microfabricated DNA Analysis Device
1996 • 728 citations
Effects of Injection Schemes and Column Geometry on the Performance of Microchip Electrophoresis Devices
1994 • 658 citations
Ultra-high-speed DNA fragment separations using microfabricated capillary array electrophoresis chips.
1994 • 588 citations
Capillary Electrophoresis Chips with Integrated Electrochemical Detection
1998 • 536 citations
Micromachining of capillary electrophoresis injectors and separators on glass chips and evaluation of flow at capillary intersections
1994 • 357 citations
High-Speed DNA Genotyping Using Microfabricated Capillary Array Electrophoresis Chips
1997 • 316 citations
Integrated Microdevice for DNA Restriction Fragment Analysis
1996 • 306 citations
DNA Sequencing on Microfabricated Electrophoretic Devices
1998 • 211 citations
Integrated Capillary Electrophoresis Devices with an Efficient Postcolumn Reactor in Planar Quartz and Glass Chips
1996 • 196 citations
Rapid DNA Sequencing of More Than 1000 Bases per Run by Capillary Electrophoresis Using Replaceable Linear Polyacrylamide Solutions
1996 • 186 citations
Dispersion Sources for Compact Geometries on Microchips
1998 • 184 citations
Separation of 4‐color DNA sequencing extension products in noncovalently coated capillaries using low viscosity polymer solutions
1998 • 166 citations
DNA typing in thirty seconds with a microfabricated device
1997 • 145 citations
Routine DNA Sequencing of 1000 Bases in Less Than One Hour by Capillary Electrophoresis with Replaceable Linear Polyacrylamide Solutions
1998 • 132 citations
Manipulation of Sample Fractions on a Capillary Electrophoresis Chip
1995 • 110 citations
Use of Non-Cross-Linked Polyacrylamide for Four-Color DNA Sequencing by Capillary Electrophoresis Separation of Fragments up to 640 Bases in Length in Two Hours
1995 • 104 citations
Characterization of high molecular mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis
1998 • 94 citations
Improved Single-Strand DNA Sizing Accuracy in Capillary Electrophoresis
1997 • 87 citations
Analysis of Nucleic Acids by Capillary Electrophoresis
1997 • 75 citations
Capillary Electrophoresis.
1991 • 26 citations
Electrophoretic resolution versus fluctuations of the lateral dimensions of a capillary
1995 • 12 citations
Three‐dimensional imaging of DNA fragments during electrophoresis using a confocal detector
1995 • 3 citations