High-molecular-weight carrier ampholytes for isoelectric focusing of peptides
Data up to Jan 2025
Total Citations Per Year
Abstract
References (31)
Protides of the Biological Fluids
1969 • 1,623 citations
Isoelectric focusing in polyacrylamide gels
1971 • 403 citations
Isoelectric Fractionation, Analysis, and Characterization of Ampholytes in Natural pH Gradients. II. Buffering Capacity and Conductance of Isoionic Ampholytes.
1962 • 335 citations
Ultrathin‐layer isoelectric focusing in 50–100 μm polyacrylamide gels on silanized glass plates or polyester films
1980 • 318 citations
Hydrophobic interaction chromatography
1974 • 314 citations
Synthesis and Isoelectric Fractionation of Carrier Ampholytes.
1969 • 270 citations
Analytical techniques for cell fractions XXIV. Isoelectric point standards for two-dimensional electrophoresis
1979 • 187 citations
Ultrathin-layer isoelectric focusing in polyacrylamide gels on cellophane
1978 • 162 citations
Isoelectric focusing of peptides
1978 • 123 citations
Isoelectric focusing of heparin
1978 • 65 citations
New developments in isoelectric focusing
1980 • 53 citations
Aggregation of ampholine on heparin and other acidic polysaccharides in isoelectric focusing
1978 • 41 citations
Binding of polyanions to carrier ampholytes in isoelectric focusing
1978 • 41 citations
Peptide analysis by isoelectric focusing in polyacrylamide gels
1978 • 39 citations
Binding of Ampholine to transfer RNA
1976 • 37 citations
Protein Fractionation At Subzero Temperatures
1978 • 33 citations
Gas chromatography of the amino acid esters in ammonia
1962 • 32 citations
Isoelectric focusing of oligopeptides: Detections by specific stains
1979 • 28 citations
Lack of interaction between hormonal proteins and synthetic carrier ampholytes (Ampholine)
1975 • 28 citations
Itaconic acid carrier ampholytes for isoelectric focusing
1977 • 24 citations
A new method for the concentration of high and low molecular weight substances and for their recovery following gel electrophoresis, partition and precipitation experiments
1971 • 22 citations
Iodine stain for detection of peptides after isoelectric focusing
1980 • 21 citations
THE USE OF GEL ISOELECTROFOCUSING IN MONITORING CHEMICAL MODIFICATIONS OF PROTEINS*
1973 • 17 citations
Molecular weight distribution of carrier ampholytes for isoelectric focusing
1981 • 17 citations
Synthesis of carrier ampholyte mixtures suitable for isoelectric fractionation analysis
1980 • 16 citations
Mitogenic and inhibitory effects of carrier ampholytes on quiescent and stimulated human diploid lung fibroblasts
1979 • 15 citations
Useful modification of Pauly's reagent
1978 • 12 citations
Some optical properties of carrier ampholytes for isoelectric focusing
1975 • 12 citations
Study of the feasibility of separation of carrier ampholytes from peptides by hydrophobic interaction chromatography on octyl-sepharose
1980 • 11 citations
Fingerprinting of casein digests by isoelectric focusing and SDS electrophoresis
1980 • 9 citations
Gel chromatographic comparison of the molecular weight distributions of ampholine, servalyte and pharmalyte carrier ampholytes used in isoelectric focusing
1980 • 8 citations