Determination of formaldehyde with an enzyme-coated piezoelectric crystal detector
Data up to Jan 2025
Total Citations Per Year
Abstract
References (31)
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
1959 • 9,102 citations
Use of quartz vibration for weighing thin films on a microbalance
1959 • 6,792 citations
Sodium Borohydride, Its Hydrolysis and its Use as a Reducing Agent and in the Generation of Hydrogen1
1953 • 1,043 citations
Piezoelectric Sorption Detector.
1964 • 772 citations
Applications of the piezoelectric crystal detector in analytical chemistry
1977 • 233 citations
Sampling of formaldehyde in air with coated solid sorbent and determination by high performance liquid chromatography
1980 • 143 citations
Messung von Plattenschwingungen sehr kleiner Amplitude durch Lichtstrommodulation
1964 • 142 citations
A new design and coatings for piezoelectric crystals in measurement of trace amounts of sulfur dioxide
1974 • 85 citations
Electrode indicator technique for measuring low levels of cyanide
1972 • 84 citations
Piezoelectric detectors for organophosphorus compounds and pesticides
1972 • 67 citations
Detection of explosives with a coated piezoelectric quartz crystal
1979 • 66 citations
The detection of ammonia and nitrogen dioxide at the parts per billion level with coated piezoelectric crystal detectors
1975 • 64 citations
Detection of ammonia in ambient air with coated piezoelectric crystal detector
1978 • 63 citations
Detection of hydrogen chloride gas in ambient air with a coated piezoelectric quartz crystal
1978 • 54 citations
Colorimetric Determination of Cyanide and Thiocyanate
1953 • 45 citations
Monitoring of hydrogen, methane, and hydrocarbons in the atmosphere
1970 • 45 citations
Determination of Cyanides in Water and Waste Samples
1954 • 42 citations
A piezoelectric-crystal mercury monitor
1978 • 41 citations
A Gas Chromatograph Based on the Piezoelectric Detector
1971 • 40 citations
Simple piezoelectric probe for detection and measurement of sulfur dioxide
1973 • 40 citations
Analytical performance of the piezoelectric crystal detector
1974 • 39 citations
A coated piezoelectric crystal detector for the selective detection and determination of hydrogen sulfide in the atmosphere
1978 • 32 citations
Chromatographic design and temperature-related characteristics of the piezoelectric detector
1976 • 26 citations
Measurement of SO2in Air Using Coated Piezoelectric Crystal Detectors
1975 • 25 citations
Continuous determination of free cyanide in effluents using silver ion selective electrode
1976 • 22 citations
Cobalt boride as a heterogeneous catalyst
1969 • 18 citations
The determination of cyanides in steelworks effluents with a cyanide-selective electrode
1976 • 15 citations
Square wave polarographic determination of cyanide ions
1972 • 7 citations
Coulometric Determination of Total Cyanide in Effluent and Wastewater
1978 • 7 citations
Ligand displacement method for the determination of total cyanide
1981 • 5 citations
Voltametrische Titration von Cyanid mit Quecksilber(II)-chlorid und ihre Anwendung zur Cyanidbestimmung in Wasser und Abwasser
1977 • 4 citations