Kinetic model of pH-based potentiometric enzymic sensors. Part 4. Enzyme loading and lifetime factors
Data up to Jan 2025
Total Citations Per Year
Abstract
References (28)
Kinetic behavior of enzymes immobilized in artificial membranes
1972 • 109 citations
pH-based enzyme potentiometric sensors. Part 1. Theory
1985 • 103 citations
Sensitive detection of pesticides using a differential ISFET-based system with immobilized cholinesterases
1993 • 93 citations
Theoretical evaluation of the steady-state response of potentiometric enzyme electrodes
1980 • 65 citations
Some aspects of the kinetics of enzymic reactions
1953 • 65 citations
Fourier analysis of the transient response of potentiometric enzyme electrodes
1977 • 64 citations
Immobilized Enzymes in Analytical and Clinical Chemistry: Fundamentals and Applications
1980 • 60 citations
Comparison of immobilization methods for the development of an acetylcholinesterase biosensor
1993 • 54 citations
Urea sensors based on PVC membrane pH electrode
1994 • 35 citations
Theory of the biocatalytic membrane electrode
1983 • 31 citations
Kinetic model of pH-based potentiometric enzymic sensors. Part 1. Theoretical considerations
1991 • 30 citations
Immunoenzymatic assay using CHEMFET devices
1991 • 28 citations
Steady-state theory of biocatalytic membrane electrodes
1981 • 27 citations
Comparison of pH-Membrane Enzyme Electrodes for Urea with Covalently Bound Enzyme.
1994 • 26 citations
Theoretical evaluation of the performance of enzyme electrodes and of enzyme reactors
1980 • 21 citations
CHEMFET Devices for biomedical and environmental applications
1992 • 21 citations
Kinetic model of pH-based potentiometric enzymic sensors. Part 3. Experimental verification
1992 • 20 citations
Insecticide determination with enzyme electrodes using different enzyme immobilization techniques
1992 • 19 citations
Availability and development of an enzyme immunomicrosensor based on an ISFET for human immunoglobulins
1990 • 18 citations
Design of enzyme‐pH electrodes
1987 • 17 citations
An algebraic equation for the steady-state response of enzyme-pH electrodes and field effect transistors
1987 • 17 citations
Ein neuer Mikroschmelzpunkt- und Sublimationsapparat mit vollst�ndig eingebautem Thermometer
1937 • 16 citations
Characteristics of unbuffered gel‐immobilized urease particles. II. Overall rate of reaction
1977 • 16 citations
Ein Beitrag zum Funktionsmechanismus der ureatischen Harnstoffspaltung
1972 • 14 citations
Analysis of Urea Hydrolysis by Immobilized Urease in Urea‐Sensing Electrodes
1987 • 11 citations
Simplex method for the computation of analytical parameters of potentiometric sensors
1993 • 10 citations
Kinetic model of pH-based potentiometric enzymic sensors. Part 2. Method of fitting
1992 • 9 citations
Theoretical model of the response of pH‐based enzyme sensors
1991 • 5 citations