Back to search

A new method to model change in cutaneous blood flow due to mechanical skin irritation

Data up to Jan 2025

Published2005
Citations11
References24

Total Citations Per Year

Abstract

References (24)

Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow

1980 • 1,109 citations

The Blood Vessels of the Human Skin and Their Responses.

1928 • 882 citations

Model for laser Doppler measurements of blood flow in tissue

1981 • 832 citations

Physiologie des Menschen

2007 • 796 citations

A New Instrument for Continuous Measurement of Tissue Blood Flow by Light Beating Spectroscopy

1980 • 606 citations

Laser-Doppler Flowmetry

2013 • 335 citations

Acute Effects of Substance P and Calcitonin Gene-Related Peptide in Human Skin – A Microdialysis Study

2000 • 242 citations

Principles of Laser-Doppler Flowmetry

1990 • 196 citations

Laser-doppler flowmetry

1990 • 169 citations

Differential ability of human cutaneous nociceptors to signal mechanical pain and to produce vasodilatation

1994 • 164 citations

The Acute Effect of Smoking on Cutaneous Microcirculation Blood Flow in Habitual Smokers and Nonsmokers

1998 • 104 citations

Physiologie des Menschen

1995 • 78 citations

Finite element analysis of blood flow through biological tissue

1997 • 55 citations

Poroelasticity of saturated solids with an application to blood perfusion

1996 • 45 citations

A FINITE ELEMENT MIXTURE MODEL FOR HIERARCHICAL POROUS MEDIA

1997 • 42 citations

Effect of oral ethanol intake on muscle sympathetic nerve activity and cardiovascular functions in humans

1995 • 40 citations

Low Reynolds number steady state flow through a branching network of rigid vessels: I. A mixture theory

1989 • 35 citations

A dynamic nonlinear lumped parameter model for skeletal muscle circulation

1989 • 26 citations

Mechanical blood-tissue interaction in contracting muscles

1998 • 26 citations

Low Reynolds number steady state flow through a branching network of rigid vessels: II. A finite element mixture model

1989 • 26 citations

Finite-element simulation of blood perfusion in muscle tissue during compression and sustained contraction

1997 • 22 citations

Spatial interaction between tissue pressure and skeletal muscle perfusion during contraction

2001 • 18 citations

Confounding factors in non-invasive tests of neurovascular function in diabetes mellitus.

1992 • 10 citations

A three-layer continuous model of porous media to describe the first phase of skin irritation

2005 • 5 citations

Cited By (0)

Loading...